Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STERLING DRILLING COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STERLING DRILLING COMPANY in SEC 4, TWP 20, R 11, 500 FNL, 2080 FEL, ELLINWOOD, KS 67526 (NAICS 213111). OSHA activity number 340112085.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sterling Drilling Company — free Get an email when a new federal OSHA severe-injury report for Sterling Drilling Company is published. One employer, no account, unsubscribe in one click.
Site address
SEC 4, TWP 20, R 11, 500 FNL, 2080 FEL
City
ELLINWOOD
State
KS
ZIP
67526
Mailing
P.O. BOX 1006, PRATT, KS 67124
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
15
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Deleted Other-than-serious 1 instance 15 exposed
Issued
Feb 2, 2015
Abate by
Mar 6, 2015
Penalty
Initial $3,500 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): OSH ACT of 1970 SECTION (5)(a)(1): The employer did not furnish employment and  a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck by hazards:    Employees working at or near the drilling tongs were exposed to struck-by hazards from the uncontrolled rotational movement of the manual drilling tongs.  The shackle pin used to secure the wire rope snub line to the derrick, was the screw pin type and did not have a secondary means of securement to prevent the pin from separating from the shackle.    Among other methods, feasible and acceptable methods of abatement would be to follow the American Petroleum Institute (API) Recommended Practices in API RP 54, using a rotating pin type shackle, which has a secondary securement system, using a nut and cotter to secure the snub line to the derrick.  API Recommended Practices 54, Section 9.2.8 states "Bolts, nuts, and pins on elevators, wire rope, and catlines, as well as sheave and other anchor bolts in the derrick or mast should be secured".
Recent events (2)
  • — I (O) $0
  • — Z (S) $3500

View Sterling Drilling Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340112085.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.