Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: REID ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of REID ROOFING, INC. in 3056 SOUTHPORT AVE., CHICAGO, IL 60657 (NAICS 238160). OSHA activity number 340113323.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reid Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Reid Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
REID ROOFING, INC.
Site address
3056 SOUTHPORT AVE.
City
CHICAGO
State
IL
ZIP
60657
Mailing
2432 IRVING PARK RD., CHICAGO, IL 60618
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.416 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 17, 2015
Abate by
Feb 23, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:      a)  An employee was not protected against accidental contact with energized power lines while performing roofing work to an existing residential building.  The power lines have a voltage rating of 120/240 volts.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Feb 17, 2015
Abate by
Feb 23, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.501(b)(13):  Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor were the   employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):    a)  Employees performing roofing work were not protected from fall hazards of approximately 32 feet from a roof with a 7/12 pitch.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.503 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Feb 17, 2015
Abate by
May 4, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:     a)  Employees were exposed to fall hazards while performing roofing work and the employer did not provide a training program to recognize fall hazards and the procedures to be followed in order to minimize those hazards.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

View Reid Roofing, INC.'s full OSHA safety record →