NEWBURYPORT, MA —
OSHA Inspection: PCI SYNTHESIS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PCI SYNTHESIS in 9 OPPORTUNITY WAY, NEWBURYPORT, MA 01950 (NAICS 325412). OSHA activity number 340168202.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PCI SYNTHESIS
- Site address
- 9 OPPORTUNITY WAY
- City
- NEWBURYPORT
- State
- MA
- ZIP
- 01950
- Mailing
- 9 OPPORTUNITY WAY, NEWBURYPORT, MA 01950
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325412
- Employees
- 83
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.1450 E01
- Issued
- Jun 5, 2015
- Abate by
- Jul 23, 2015
- Penalty
- Initial $4,950 · Current $2,970 Reduced
General-duty citation text
29 CFR 1910.1450(e)(1): Where hazardous chemicals were used in the workplace, the employer did not develop and carry out the provisions of a written Chemical Hygiene Plan which is to be capable of protecting employees from health hazards associated with hazardous chemicals: (a) Location - Establishment On or about 1/7/15 the employer did not carry out the provisions of the Chemical Hygiene Plan by performing annual hood evaluations. (b) Location - Establishment On or about 1/7/15 the employer did not carry out the provisions of the Chemical Hygiene Plan by evaluating the ventilation efficiency of glove boxes, gas cabinets, and other ventilation engineering controls (protective equipment) to ensure proper and adequate performance.
Recent events (2)
- — I (S) $2970
- — Z (S) $4950
1910.1450 E03 III
- Issued
- Jun 5, 2015
- Abate by
- Jul 23, 2015
- Penalty
- Initial $4,950 · Current $2,970 Reduced
General-duty citation text
29 CFR 1910.1450(e)(3)(iii): The employer's Chemical Hygiene Plan did not include a requirement that fume hoods and other protective equipment functioned properly and did not include specific measures that would be taken to ensure proper and adequate performance of such equipment: (a) Location - Establishment On or about 1/7/15 the employer's Chemical Hygiene Plan did not include specific measures that would be taken to ensure proper and adequate performance of other protective engineering controls including, but not limited to, glove boxes, gas cabinets, and other local exhaust ventilation.
Recent events (2)
- — I (S) $2970
- — Z (S) $4950
1910.1450 E03 VII
- Issued
- Jun 5, 2015
- Abate by
- Jul 23, 2015
- Penalty
- Initial $9,900 · Current $5,940 Reduced
General-duty citation text
29 CFR 1910.1450(e)(3)(vii): The employer's Chemical Hygiene Plan did not include the designation of personnel responsible for implementation of the Chemical Hygiene Plan, including the assignment of a Chemical Hygiene Officer; and when appropriate, establishment of a chemical hygiene committee: (a) Location - Establishment On or about 1/7/15, the employer's Chemical Hygiene Plan did not designate the personnel responsible for implementation of the Chemical Hygiene Plan and the personnel assigned as the Chemical Hygiene Officer. Polycarbon Industries, Inc. DBA PCI Synthesis was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 1910.1450(e)(3)(vii), which was contained in OSHA inspection number 927156, citation number 1, item number 5a and was affirmed as a final order on 11/2/2013, with respect to a workplace located at 88 Jackson Rd., Bldg. 649, Devens, MA 01434.`
Recent events (2)
- — I (R) $5940
- — Z (R) $9900
1910.1450 E04
- Issued
- Jun 5, 2015
- Abate by
- Jul 23, 2015
- Penalty
- Initial $24,750 · Current $12,000 Reduced
General-duty citation text
29 CFR 1910.1450(e)(4): The employer did not review and evaluate the effectiveness of the Chemical Hygiene Plan at least annually and update it as necessary: (a) Location - Establishment On or about 1/7/15, the employer did not review and evaluate the effectiveness of the Chemical Hygiene Plan at least annually. Polycarbon Industries, Inc. DBA PCI Synthesis was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 1910.1450(e)(4), which was contained in OSHA inspection number 927156, citation number 2, item number 1 and was affirmed as a final order on 11/2/2013, with respect to a workplace located at 88 Jackson Rd., Bldg. 649, Devens, MA 01434.
Recent events (2)
- — I (R) $12000
- — Z (R) $24750
More inspections at PCI Synthesis
View PCI Synthesis's full OSHA safety record →
More inspections in this industry (NAICS 325412)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340168202.