NEWBURYPORT, MA —
OSHA Inspection: PCI SYNTHESIS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PCI SYNTHESIS in 9 OPPORTUNITY WAY, NEWBURYPORT, MA 01950 (NAICS 325412). OSHA activity number 345364897.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PCI SYNTHESIS
- Site address
- 9 OPPORTUNITY WAY
- City
- NEWBURYPORT
- State
- MA
- ZIP
- 01950
- Mailing
- 9 OPPORTUNITY WAY, NEWBURYPORT, MA 01950
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325412
- Employees
- 87
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.106 E06 I
- Issued
- Oct 15, 2021
- Abate by
- Apr 21, 2022
- Penalty
- Initial $10,513 · Current $5,000 Reduced
13712460
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent ignition of flammable vapors by sources including, but not limited to, open flames, lightning, smoking, cutting and welding, hot surfaces, frictional heat, static, electrical and mechanical sparks, and spontaneous ignition including heat-producing chemical reactions, and radiant heat: (a) Location - 9 Opportunity Way, Newburyport, MA: On or about June 11, 2021, pumps used for the transfer of flammable liquids in a manufacturing process were not grounded to prevent the accumulation of static electricity.
Recent events (3)
- — F (S) $5000
- — C (S) $10513
- — Z (S) $10513
1910.120 Q02 VII
- Issued
- Oct 15, 2021
- Abate by
- Apr 21, 2022
- Penalty
- Initial $7,510 · Current $3,000 Reduced
13712460
General-duty citation text
29 CFR 1910.120(q)(2)(vii): The emergency response plan did not address, to the extent not addressed elsewhere, decontamination: (a) Location - 9 Opportunity Way, Newburyport, MA: On or about June 11, 2021, the facility's integrated contingency plan does not address the setting up of decontamination stations and the decontamination of personnel and equipment.
Recent events (3)
- — F (O) $3000
- — C (S) $7510
- — Z (S) $7510
1910.120 Q02 X
- Issued
- Oct 15, 2021
- Abate by
- Apr 21, 2022
- Penalty
- Initial $0 · Current $0
13712460
General-duty citation text
29 CFR 1910.120(q)(2)(x): The emergency response plan did not address, to the extent not addressed elsewhere, critique of response and follow-up: (a) Location - 9 Opportunity Way, Newburyport, MA: On or about June 11, 2021, the facility's integrated contingency plan does not provide procedures for the critique of emergency responses.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
More inspections at PCI Synthesis
View PCI Synthesis's full OSHA safety record →
More inspections in this industry (NAICS 325412)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345364897.