CLEARWATER, FL —
OSHA Inspection: BELQUETTE INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of BELQUETTE INC. in 3634 131ST AVENUE NORTH, CLEARWATER, FL 33762 (NAICS 333244). OSHA activity number 340183698.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BELQUETTE INC.
- Site address
- 3634 131ST AVENUE NORTH
- City
- CLEARWATER
- State
- FL
- ZIP
- 33762
- Mailing
- 3634 131ST AVENUE NORTH, CLEARWATER, FL 33762
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333244
- Employees
- 25
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.151 C
- Issued
- Feb 10, 2015
- Abate by
- Mar 9, 2015
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) Ink Room - No eyewash was provided where cleaners containing alkalines were used, on or about January 15, 2015.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.215 A04
- Issued
- Feb 10, 2015
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: a) Cut Room - Central Machinery 6" bench grinder, number 37822, work rest on the right side was 5/16" from the wheel, on or about January 15, 2015.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.215 B09
- Issued
- Feb 10, 2015
- Abate by
- Feb 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) Cut Room - Central Machinery 6" bench grinder, number 37822, was missing the tongue guard, on or about January 15, 2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Feb 10, 2015
- Abate by
- Mar 9, 2015
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Facility-wide - There was no written hazard communication program in place, on or about January 15, 2015. Chemicals used included 2-methoxymethylethoxy propanol, propylene glycol, ethylene glycol, and hydrocracked and hydrotreated paraffinic oils.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.1200 F05
- Issued
- Feb 10, 2015
- Abate by
- Feb 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: a) Ink Room - Secondary bottles of chemicals, including but not limited to, inks, cleaning solutions and vacuum pump oil were not provided with labels, on or about January 15, 2015.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G01
- Issued
- Feb 10, 2015
- Abate by
- Feb 17, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) Pre-treat Room - There were containers on the floor in front of the electrical panels, on or about January 15, 2015.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 333244)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340183698.