Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BELQUETTE INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BELQUETTE INC. in 3634 131ST AVENUE NORTH, CLEARWATER, FL 33762 (NAICS 333244). OSHA activity number 340183698.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Belquette INC. — free Get an email when a new federal OSHA severe-injury report for Belquette INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BELQUETTE INC.
Site address
3634 131ST AVENUE NORTH
City
CLEARWATER
State
FL
ZIP
33762
Mailing
3634 131ST AVENUE NORTH, CLEARWATER, FL 33762
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333244
Employees
25
Ownership type
A

6 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 10, 2015
Abate by
Mar 9, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a) Ink Room - No eyewash was provided where cleaners containing alkalines were used, on or about January 15, 2015.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 10, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  a) Cut Room - Central Machinery 6" bench grinder, number 37822, work rest on the right side was 5/16" from the wheel, on or about January 15, 2015.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 10, 2015
Abate by
Feb 23, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a) Cut Room - Central Machinery 6" bench grinder, number 37822, was missing the tongue guard, on or about January 15, 2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 25 exposed
Issued
Feb 10, 2015
Abate by
Mar 9, 2015
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  a) Facility-wide - There was no written hazard communication program in place, on or about January 15, 2015. Chemicals used included 2-methoxymethylethoxy propanol, propylene glycol, ethylene glycol, and hydrocracked and hydrotreated paraffinic oils.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.1200 F05

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 10, 2015
Abate by
Feb 23, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein:  a) Ink Room - Secondary bottles of chemicals, including but not limited to, inks, cleaning solutions and vacuum pump oil were not provided with labels, on or about January 15, 2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Other-than-serious 1 instance 25 exposed
Issued
Feb 10, 2015
Abate by
Feb 17, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) Pre-treat Room - There were containers on the floor in front of the electrical panels, on or about January 15, 2015.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340183698.