Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DURA-FIBRE LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DURA-FIBRE LLC in 352 6TH STREET, MENASHA, WI 54952 (NAICS 322299). OSHA activity number 340194497.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dura-Fibre LLC — free Get an email when a new federal OSHA severe-injury report for Dura-Fibre LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DURA-FIBRE LLC
Site address
352 6TH STREET
City
MENASHA
State
WI
ZIP
54952
Mailing
352 6TH STREET, MENASHA, WI 54952
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322299
Employees
60
Ownership type
A

11 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 3, 2015
Abate by
Apr 7, 2015
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a)    On or about 1/22/2015 an employee was using an E-Stop for setup inside of machine rather then lockout.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2975

1910.147 C06 I

Deleted Serious Gravity 5 1 instance 41 exposed
Issued
Mar 3, 2015
Abate by
Apr 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   a)    On or about 1/22/2015 the company had not completed periodic inspections for their energy control program for 2014.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 6 exposed
Issued
Mar 3, 2015
Abate by
Apr 30, 2015
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:        a)    On or about 1/22/2015 the Seiko Die Cutter had an unguarded opening where the die cutter comes down on the material being processed. The nip point was approximately 21" from the control panel and approximately 8" from trimming hexagon shaft.    b)    On or about 2/12/2015 the #1 laminator glue rolls needed better nip point guarding. It was approximately 12" from the frame of the machine to the ingoing nip point on the glue rolls.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2975

1910.213 A09

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 3, 2015
Abate by
Apr 7, 2015
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.213(a)(9):   All belts, pulleys, gears, shafts, and moving parts shall be guarded in accordance with the specific requirements of 1910.219.    a)    On or about 1/22/2015 the belt and pulley guard was damaged on the 10" Belt drive table saw (Sears/Craftsman Contractor Series)  -
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.213 A12

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 3, 2015
Abate by
Apr 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.213(a)(12): The portion of circular saw(s) beneath or behind the table, where there was a possibility of contact with the saw, was not covered with a guard or exhaust hood:  a)    On or about 1/22/2015  The 10" Belt drive table saw (Sears/Craftsman Contractor Series), did not have the back of the table saw guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 3, 2015
Abate by
Apr 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    a)    On or about 1/22/2015  The 10" Belt drive table saw (Sears/Craftsman Contractor Series), did not have a hood guard on the table saw.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 3, 2015
Abate by
Apr 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:    a)    On or about 1/22/2015  The 10" Belt drive table saw (Sears/Craftsman Contractor Series), was not furnished with a spreader  to prevent material from squeezing the saw blade.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C03

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 3, 2015
Abate by
Apr 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:    a)    On or about 1/22/2015  The 10" Belt drive table saw (Sears/Craftsman Contractor Series), was not furnished with non kickback finger or dogs to prevent material throw back.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 5 6 instances 4 exposed
Issued
Mar 3, 2015
Abate by
Apr 30, 2015
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    a)    On or about 1/22/2015 there were exposed shafts on the backside of the laminator that needed guarding.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2975

1910.219 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 3, 2015
Abate by
Apr 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a)    On or about 1/22/2015 there were exposed belts and pulleys on the backside of the laminator that needed guarding.  b)    On or about 1/22/2015 the SWEED SCRAP HOPPER used for cutting banding had the pulley only partially guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E03 I

Serious Gravity 5 1 instance 4 exposed
Issued
Mar 3, 2015
Abate by
Apr 7, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):   a)    On or about 1/22/2015 there were exposed belts and pulleys on the backside of the laminator that needed guarding.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0