Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DURA-FIBRE, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DURA-FIBRE, LLC in 352 6TH ST., MENASHA, WI 54952 (NAICS 322299). OSHA activity number 343953220.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dura-Fibre, LLC — free Get an email when a new federal OSHA severe-injury report for Dura-Fibre, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
DURA-FIBRE, LLC
Site address
352 6TH ST.
City
MENASHA
State
WI
ZIP
54952
Mailing
352 6TH ST., MENASHA, WI 54952
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322299
Employees
75
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II C

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 8, 2019
Abate by
Aug 5, 2019
Penalty
Initial $10,210 · Current $10,210
29 CFR 1910.147(c)(4)(ii)(C): Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and  On or about April 19, 2019, employees were exposed to machine hazards associated with moving parts when they were engaged in servicing activities on the Balemaster (Model:  44750-10, G, J, 4, Q, T, U, X, Z, 7,Z, 9; S/N:  B0122-04-13389583).  The employer did not ensure the energy control procedure, Baler 3500 & Cyclone System/Baler Utility, had specific procedural steps for the transfer of lockout devices.
Recent events (2)
  • — I (S) $10210
  • — Z (S) $10210

1910.147 F03 II D

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 8, 2019
Abate by
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee shall affix a personal lockout or tagout device to the group lockout device, group lockbox, or comparable mechanism when he or she begins work, and shall remove those devices when he or she stops working on the machine or equipment being serviced or maintained.  On or about April 19, 2019, each authorized employee did not affix a personal lockout device when performing servicing work on the Balemaster (Model:  44750-10, G, J, 4, Q, T, U, X, Z, 7,Z, 9; S/N:  B0122-04-13389583) exposing employees to accidental/inadvertent restart of the equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 F01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 8, 2019
Abate by
Aug 5, 2019
Penalty
Initial $10,210 · Current $0 Reduced
29 CFR 1910.147(f)(1): Testing or positioning of machines, equipment or components thereof. In situations in which lockout or tagout devices must be temporarily removed from the energy isolating device and the machine or equipment energized to test or position the machine, equipment or component thereof, the following sequence of actions shall be followed as outlined in 29 CFR 1910.147(f)(1)(i)-(v):    On or about April 19, 2019, employee(s) the repositioning of the hydraulic ram of the Balemaster (Model:  44750-10, G, J, 4, Q, T, U, X, Z, 7,Z, 9; S/N:  B0122-04-13389583) and did not ensure all employees were removed from the equipment exposing employees to caught in and struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10210

1910.147 C04 I

Other-than-serious 1 instance 1 exposed
Issued
Jul 8, 2019
Abate by
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   On or about April 15, 2019, the Marquip (Model:  13884-3U01, S/N:  POM:  124) slitter did not have written procedure developed prior to performing servicing activities exposing employees to unexpected restart.  Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 II

Other-than-serious 1 instance 5 exposed
Issued
Jul 8, 2019
Abate by
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.  The employer's certification that the periodic inspection was performed did not include the machine or equipment on which the energy control procedure was being utilized and the person performing the inspection.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Dura-Fibre, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343953220.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.