TERRE HAUTE, IN —
OSHA Inspection: US DEPARTMENT OF TRANSPORATION, FEDERAL AVIATION ADMINISTRATIONS, TERRE HAUTE, IN
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of US DEPARTMENT OF TRANSPORATION, FEDERAL AVIATION ADMINISTRATIONS, TERRE HAUTE, IN in 508 S. AIRPORT STREET, TERRE HAUTE, IN 47803 (NAICS 488111). OSHA activity number 340196393.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 508 S. AIRPORT STREET
- City
- TERRE HAUTE
- State
- IN
- ZIP
- 47803
- Mailing
- 508 S. AIRPORT STREET, TERRE HAUTE, IN 47803
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488111
- Employees
- 26
- Ownership type
- D
Citations
6 citations on file for this inspection.
1910.23 D01 III
- Issued
- Feb 18, 2015
- Abate by
- Apr 6, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1)(iii): On stairways less than 44 inches wide having both sides open, one stair railing on each side. a) On or about Monday, January 26, 2015, the open stairway, leading the RVR Building Platform, was equipped with only one handrail. Employees were exposed to falls from elevation which could cause broken bones, fractures, and possibly even death.
Recent events (1)
- — Z (S) $0
1910.23 E01
- Issued
- Feb 18, 2015
- Abate by
- Apr 6, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(e)(1): A standard railing shall consist of top rail, intermediate rail, and posts, and shall have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level. The top rail shall be smooth-surfaced throughout the length of the railing. The intermediate rail shall be approximately halfway between the top rail and the floor, platform, runway, or ramp. The ends of the rails shall not overhang the terminal posts except where such overhang does not constitute a projection hazard. a) On or about Monday, January 26, 2015, the open stairway, leading to the RVR Building Platform, was not equipped with an intermediate rail. Employees were exposed to falls from elevation which could cause broken bones, fractures, and possibly even death.
Recent events (1)
- — Z (S) $0
1910.303 B07 IV
- Issued
- Feb 18, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There shall be no damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. a) On or about Monday, January 26, 2015, in the HUF Air Surveillance Radar Room, a burned electrical receptacle was being utilized as a power source. The employees were exposed to electrical burns, electric shock or electrocution.
Recent events (1)
- — Z (S) $0
1910.305 B01 II
- Issued
- Feb 18, 2015
- Abate by
- Feb 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed. Live electrical parts were exposed due to a missing knockout approximately 1 in diameter. a) On or about Monday, January 26, 2015, on the north wall of the supervisors office, a knockout was missing in the electrical box. The missing knockout exposed employees to live parts which could result in electrical burns, electric shock and possible death by electrocution.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV B
- Issued
- Feb 18, 2015
- Abate by
- Mar 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: a) On or about Monday January 26, 2015, in the Flight Service Station building, an electrical calibration cable was running through a 3 inch hole that was cut in an existing door that lead into a mechanical room. The pinched cable exposed employees to possible electrical burns, electrical shock and death by electrocution.
Recent events (1)
- — Z (S) $0
1910.22 A01
- Issued
- Feb 18, 2015
- Abate by
- Apr 6, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. a) On or about Monday, January 26, 2015, in the break room, the carpet was totally separating across the floor. Employees were exposed to slips, trips and falls which could result in bruises, cuts and broken bones.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 488111)
More inspections in IN
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340196393.