FORT WORTH, TX —
OSHA Inspection: ADS STEEL SERVICES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADS STEEL SERVICES in 7461 W. VICKERY BLVD, FORT WORTH, TX 76116 (NAICS 333511). OSHA activity number 340212117.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADS STEEL SERVICES
- Site address
- 7461 W. VICKERY BLVD
- City
- FORT WORTH
- State
- TX
- ZIP
- 76116
- Mailing
- 7461 W. VICKERY BLVD, FORT WORTH, TX 76116
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333511
- Employees
- 39
- Ownership type
- A
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 27, 2015
- Abate by
- Mar 27, 2015
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: the employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees exposed to being struck by or crushed by hazards: On or about January 23, 2015, and times prior thereto, in the welding shop, the employer did not ensure that all equipment used to aid in the process of lifting and/or moving structural steel and other material was inspected, such as the 1 ton CM hoist, series 622, (no serial number) where the safety latches on the hook were missing.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1904.32 A02
- Issued
- Feb 27, 2015
- Abate by
- Mar 27, 2015
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1904.32(a)(2): At the end of each calendar year an annual summary of injuries and illnesses recorded on the OSHA 300 log was not completed in detail: On or about January 23, 2015, and times prior thereto, the employer did not create, certify, or post an annual summary for OSHA 300A logs to monitor injuries in the work place for the years 2013 and 2014.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.37 A03
- Issued
- Feb 27, 2015
- Abate by
- Mar 27, 2015
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: On or about January 23, 2014, and times prior thereto, the path to the exit doors were blocked exposing employees to entrapment and fire hazards: a. In the cutting room the exit door was blocked by steel material used for fabrication. b. In the storage and tool maintenance room, the exit door was blocked by wooden panels.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.37 B02
- Issued
- Feb 27, 2015
- Abate by
- Mar 27, 2015
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": On or about January 23, 2014, and times prior thereto, the employer did not ensure the exit doors were equipped or identified with an exit sign. The employees were exposed to entrapment hazards: a. In the cutting room. b. In the storage and tool maintenance room.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.212 A01
- Issued
- Feb 27, 2015
- Abate by
- Mar 27, 2015
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about January 23, 2014, and times prior thereto, chop saws used by employees to cut metal material were not equipped with a blade guard that completely enclosed the blade exposing employees to the hazard of amputation: a. In the welding shop: a Dewalt chop saw guard was tied in the up position. b. In the cutting room: a Brilliant cut off saw had a missing guard.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.243 C01
- Issued
- Feb 27, 2015
- Abate by
- Mar 27, 2015
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4)(a): On or about January 23, 2014, and times prior thereto, throughout the welding room, employees were using Dewalt portable grinders without safety guards, exposing employees to laceration hazards.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.253 B02 II
- Issued
- Feb 27, 2015
- Abate by
- Mar 27, 2015
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: On or about January 23, 2014, and times prior thereto, in the welding room, employer did not secure or store compressed gas cylinders exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.305 B01
- Issued
- Feb 27, 2015
- Abate by
- Mar 27, 2015
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about January 23, 2014, and times prior thereto, in the cutting room, an electrical outlet box was missing knock-out plugs exposing employees to electrical hazards.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1910.305 G02 III
- Issued
- Feb 27, 2015
- Abate by
- Mar 27, 2015
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: On or about January 23, 2014, and times prior thereto, in the welding room, employees were exposed to electrical hazards while using a portable electrical outlet to energize a Baileigh pipe bender which had the outer sheathing pulled away with visible internal wiring.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
More inspections at ADS Steel Services
View ADS Steel Services's full OSHA safety record →
More inspections in this industry (NAICS 333511)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340212117.