Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ADS STEEL SERVICES

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of ADS STEEL SERVICES in 7461 W. VICKERY BLVD, FORT WORTH, TX 76116 (NAICS 333511). OSHA activity number 341196442.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ADS Steel Services — free Get an email when a new federal OSHA severe-injury report for ADS Steel Services is published. One employer, no account, unsubscribe in one click.
Establishment
ADS STEEL SERVICES
Site address
7461 W. VICKERY BLVD
City
FORT WORTH
State
TX
ZIP
76116
Mailing
7461 W. VICKERY BLVD, FORT WORTH, TX 76116
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333511
Employees
39
Ownership type
A

2 citations on file for this inspection.

1910.334 A02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 28, 2016
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).    Inside the welding and cutting area, an employee used an extension cord with the outer sheathing cut exposing internal wiring to energize a Dewalt portable grinder, exposing the employee to electrical hazards.
Recent events (2)
  • — I (S) $1071
  • — Z (S) $1785

1910.253 B02 IV

Other-than-serious 1 instance 10 exposed
Issued
Jan 28, 2016
Penalty
Initial $595 · Current $357 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use.   In the welding and cutting production area, an unused but secured nitrogen compressed gas cylinder was stored without the protective cap exposing employees to struck-by hazards.
Recent events (2)
  • — I (O) $357
  • — Z (O) $595

View ADS Steel Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341196442.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.