OSHA Inspection: PRO DISPOSAL INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PRO DISPOSAL INC. in 1926 PURITAN ROAD, PORTAGE, PA 15946 (NAICS 562111). OSHA activity number 340213164.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PRO Disposal INC. — free Get an email when a new federal OSHA severe-injury report for PRO Disposal INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PRO DISPOSAL INC.
Site address
1926 PURITAN ROAD
City
PORTAGE
State
PA
ZIP
15946
Mailing
1288 WASHINGTON AVENUE, SUMMERHILL, PA 15958
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562111
Employees
7
Ownership type
A

7 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 6, 2015
Abate by
Apr 16, 2015
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition:    a) Facility, 1926 Puritan Road, Portage, PA:  On or about January 28, 2015, employees were exposed to slip and trip hazards while walking to and from their work locations due to the amount of magazines on the floor.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.37 A03

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route:  a) Facility, 1924 Puritan Road, Portage, PA:  On or about January 28, 2015, the access and egress to the employees work area on the catwalk was covered in magazines on the floor at the bottom of the steps, on the steps, and piled up next to the steps so as to provide a 21 inch opening at the stair entrance.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B06

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 6, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  a) Facility, 1926 Puritan Road, Portage, PA:  On or about January 28, 2015, employees were exposed to potential hazards in the event of an emergency because the door to exit sign on the door was not illuminated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D01

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 6, 2015
Abate by
Apr 23, 2015
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:    a) Facility, 1926 Puritan Road, Portage, PA:  On or about January 28, 2015, employees were exposed to potential hazards because the employer did not complete a workplace PPE assessment to determine what work activities needed PPE and what type of PPE would protect the employees during those activities, such as, but not limited to, working on the conveyor belt which loud and would necessitate the need for ear protection.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

1910.147 C01

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 6, 2015
Abate by
Apr 16, 2015
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a) Marathon Baler, facility, 1926 Puritan Road, Portage, PA:  On or about January 28, 2015, an employee was exposed to potential hazards while clearing jams and performing maintenance on the Baler model no. TR-10-75 without a lockout procedure or training to properly lock out the equipment.    b)  Nings Magnet, facility, 1926 Puritan Road, Portage, PA:  On or about January 28, 2015, an employee was exposed to potential hazards while greasing the fittings on the magnet serial no. K9413 without a lockout procedure or training in to properly lock out the equipment.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.219 D01

Serious Gravity 5 2 instances 2 exposed
Issued
Apr 6, 2015
Abate by
Apr 16, 2015
Penalty
Initial $2,800 · Current $2,100 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a) Facility, 1926 Puritan Road, Portage, PA:  On or about January 28, 2015, employees were exposed to rotating parts on the conveyor belt on the shaker portion of the conveyor belt and at the other end of the belt at the magnet.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $2800

1910.303 G01

Serious Gravity 1 1 instance 6 exposed
Issued
Apr 6, 2015
Penalty
Initial $2,100 · Current $1,575 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    a)  Facility, 1926 Puritan Road, Portage, PA:  On or about January 28, 2015, employees were exposed to potential hazards in the event of an emergency because access was not provided to permit ready and safe operation to the 120/480v electrical panel.
Recent events (2)
  • — I (S) $1575
  • — Z (S) $2100

View PRO Disposal INC.'s full OSHA safety record →