Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JCF ROOFING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JCF ROOFING LLC in 9665 ADELAIDE CIRCLE, HIGHLANDS RANCH, CO 80126 (NAICS 238160). OSHA activity number 340262427.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JCF Roofing LLC — free Get an email when a new federal OSHA severe-injury report for JCF Roofing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JCF ROOFING LLC
Site address
9665 ADELAIDE CIRCLE
City
HIGHLANDS RANCH
State
CO
ZIP
80126
Mailing
1860 S LOWELL BLVD, DENVER, CO 80219
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 10, 2015
Abate by
Feb 19, 2015
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:    (a)  On or about January 30, 2015, the employer did not protect employees working on the ground below roofing operations from overhead falling object hazards by ensuring the employees were wearing hard hats.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.102 A01

Serious Gravity 5 1 instance 7 exposed
Issued
Feb 10, 2015
Abate by
Feb 19, 2015
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    (a)  On or about January 30, 2015, the employer did not protect employees from eye hazards while using pneumatic nail guns without safety glasses.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.501 B13

Serious Gravity 10 1 instance 7 exposed
Issued
Feb 10, 2015
Abate by
Feb 19, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:    a) On January 30, 2015, the exposing employer, JCF Roofing, LLC, did not ensure employees, who were required to engage in re-roofing operations on a two-story residential roof, were protected from exposure to fall hazards of 19.9 feet.      Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 2 instances 8 exposed
Issued
Feb 10, 2015
Abate by
Feb 19, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    a) On or about January 30, 2015, employees were exposed to 14 to 19.9 foot fall hazards while accessing a two story residential roof using an extended ladder. The ladder rungs were not extended at least 3 feet high above the roof.    Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

View JCF Roofing LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340262427.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.