PITI, GU —
OSHA Inspection: SGS CONSTRUCTION
Special Programs inspection · Safety discipline
At a glance
On , OSHA opened a special Programs safety inspection of SGS CONSTRUCTION in FACILITY EXPANSION PROJECT - DOMESTIC WATERLINE PORT OF GUAM, PITI, GU 96915 (NAICS 237110). OSHA activity number 340308675.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SGS CONSTRUCTION
- Site address
- FACILITY EXPANSION PROJECT - DOMESTIC WATERLINE PORT OF GUAM
- City
- PITI
- State
- GU
- ZIP
- 96915
- Mailing
- PO BOX 11691, YIGO, GU 96929
What kind of inspection was it?
- Inspection type
- Special Programs (K)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 20
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.652 A01
- Issued
- Mar 27, 2015
- Abate by
- Apr 6, 2015
- Penalty
- Initial $1,530 · Current $1,530
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: a) On February 9, 2015, employees in a nearly vertical faced, 6 feet deep by 5.5 feet wide by 60 feet long section of trench for a 6 inch diameter waterline, were not protected from cave-ins, in Type C soil by a protective system.
Recent events (1)
- — Z (S) $1530
1926.652 C02 III
- Issued
- Mar 27, 2015
- Abate by
- Apr 6, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(c)(2)(iii): Manufacturer's specifications, recommendations, and limitations, and manufacturer's approval to deviate from the specifications, recommendations, and limitations shall be in written form at the jobsite during construction of the protective system. After that time this data may be stored off the jobsite, but a copy shall be made available to the Secretary upon request: a) On February 9, 2015, Griswald Machine & Engineering, Inc. manufacturer's specifications, recommendations, and limitations were not in written form at the jobsite during construction of the protective system, nor was a copy made available upon request.
Recent events (1)
- — Z (S) $0
More inspections at SGS Construction
View SGS Construction's full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340308675.