ATLANTA, GA —
OSHA Inspection: POLYAIR CORPORATION
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of POLYAIR CORPORATION in 6035-B LAGRANGE BLVD. SW, ATLANTA, GA 30336 (NAICS 339999). OSHA activity number 340405778.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- POLYAIR CORPORATION
- Site address
- 6035-B LAGRANGE BLVD. SW
- City
- ATLANTA
- State
- GA
- ZIP
- 30336
- Mailing
- 6035-B LAGRANGE BLVD. SW, ATLANTA, GA 30336
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339999
- Employees
- 78
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.95 C01
- Issued
- Apr 9, 2015
- Abate by
- May 27, 2015
- Penalty
- Initial $4,000 · Current $2,400 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: (a) Production area- An employee operating the repro grinder was exposed to continuous noise at 109.7 % of the permissible daily exposure of 85 dBA (8-hour time weighted average) or an equivalent sound level of 90.7 dBA during the 425 minute sampling period on February 19, 2015. The exposure calculation included a zero increment for the 55 minutes not sampled. The employee had not received an audiogram or noise training. (b) Production area- The Xpak operator was exposed to continuous noise at 66.5 % of the permissible daily exposure of 85 dBA (8-hour time weighted average) or an equivalent sound level of 87.1 dBA during the 444 minute sampling period on February 19, 2015. The exposure calculation included a zero increment for the 36 minutes not sampled. The employee had not received an audiogram or noise training. (c) Production area- The 6 Ft. Cast Line operator was exposed to continuous noise at 82.9 % of the permissible daily exposure of 85 dBA (8-hour time weighted average) or an equivalent sound level of 88.7 dBA during the 441 minute sampling period on February 19, 2015. The exposure calculation included a zero increment for the 39 minutes not sampled. The employee had not received an audiogram or noise training. (d) Production area- The 4 Ft. Cast Line operator was exposed to continuous noise at 86.0 % of the permissible daily exposure of 85 dBA (8-hour time weighted average) or an equivalent sound level of 88.9 dBA during the 439 minute sampling period on February 19, 2015. The exposure calculation included a zero increment for the 41 minutes not sampled. The employee had not received an audiogram or noise training. (e) Production area- A 4 Ft. Cast Line helper was exposed to continuous noise at 80.2 % of the permissible daily exposure of 85 dBA (8-hour time weighted average) or an equivalent sound level of 88.4 dBA during the 438 minute sampling period on February 19, 2015. The exposure calculation included a zero increment for the 42 minutes not sampled. The employee had not received an audiogram or noise training. An effective hearing conservation program would include, initial baseline and annual audiograms, making hearing protectors available, and initial and annual noise training.
Recent events (2)
- — I (S) $2400
- — Z (S) $4000
1910.1200 E01
- Issued
- Apr 9, 2015
- Abate by
- May 5, 2015
- Penalty
- Initial $3,000 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Production area- The employer had not established a written hazard communication program for employees exposed to hazardous substances such as, but not limited to, an Orange Cleaner Degreaser containing 2 butoxyethanol, H9195 Red adhesive containing mineral oil, and Amtone-PA Green Color Concentrate containing iron oxide and titanium dioxide.
Recent events (2)
- — I (S) $1800
- — Z (S) $3000
1910.1200 F05 I
- Issued
- Apr 9, 2015
- Abate by
- May 5, 2015
- Penalty
- Initial $0 · Current $0
0435
General-duty citation text
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: (a) Eco-lite Line- The employer did not ensure that a spray bottle of an Orange Cleaner Degreaser containing 2-butoxyethanol was properly labeled with the content contained inside.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 F05 II
- Issued
- Apr 9, 2015
- Abate by
- May 5, 2015
- Penalty
- Initial $0 · Current $0
0435
General-duty citation text
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: (a) Eco-lite Line- The employer did not ensure that a spray bottle of an Orange Cleaner Degreaser containing 2-butoxyethanol was properly labeled with the appropriate hazard warnings.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Apr 9, 2015
- Abate by
- May 5, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) Production area- The employer had not provided hazard communication training to employees exposed to hazardous substances such as, but not limited to, an Orange Cleaner Degreaser containing 2-butoxyethanol, H9195 Red adhesive containing mineral oil, and Amtone-PA Green Color Concentrate containing iron oxide and titanium dioxide.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Polyair Corporation
View Polyair Corporation's full OSHA safety record →
More inspections in this industry (NAICS 339999)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340405778.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.