Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VICTOR INSULATORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VICTOR INSULATORS, INC. in 280 MAPLE AVENUE, VICTOR, NY 14564 (NAICS 327113). OSHA activity number 340466762.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Victor Insulators, INC. — free Get an email when a new federal OSHA severe-injury report for Victor Insulators, INC. is published. One employer, no account, unsubscribe in one click.
Site address
280 MAPLE AVENUE
City
VICTOR
State
NY
ZIP
14564
Mailing
280 MAPLE AVENUE, VICTOR, NY 14564
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327113
Employees
100
Ownership type
A

4 citations on file for this inspection.

1910.27 D03

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 16, 2015
Abate by
Aug 20, 2015
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.27(d)(3): The side rails of through or side-step ladder extensions did not extend 3 1/2 feet above paraphets and landings.    a)  Filter Press Area, on or about 3/13/15: The ladder used to access the Brown Belt did not have side rails extending above the landing to allow for safe access.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.23 C01

Repeat Gravity 5 3 instances 2 exposed
Issued
Jul 16, 2015
Abate by
Aug 20, 2015
Penalty
Initial $5,600 · Current $3,360 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:  Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard:      a)  Filter Press Brown Belt, on or about 3/13/15:  Open sided work platform was not equipped with a standard railing.  Employee exposed to a 5 foot 10 inch fall hazard.    b)  Filter Press Green Belt, on or about 3/13/15: Open sided work platform was not equipped with a standard railing.  Employee exposed to a 4 foot fall hazard.    c)  Department 44, Blow Off Booth, on or about 3/12/15:  Open sided floor at the outside corner of the blow off booth was not equipped with a standard railing.  Employee exposed to a 5 foot 6 inch fall hazard.       Victor Insulators, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.23(c)(1), which was contained in OSHA inspection number 314352204, citation number 1, item number 1a, and was affirmed as a final order on 8/082011, with respect to a workplace located at 280 Maple Ave., Victor, NY.
Recent events (2)
  • — I (R) $3360
  • — Z (R) $5600

1910.212 A01

Repeat Gravity 5 5 instances 8 exposed
Issued
Jul 16, 2015
Abate by
Aug 20, 2015
Penalty
Initial $8,400 · Current $5,040 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)  Distribution Department, on or about 3/12/15:  Line 2 Hot Press, rotating capper was not provided with a guard.    b) Bend Moment Test Area, on or about 3/13/15:  The bend moment tester was not provided with guarding over the roller shafts and nip points where the roller and ceramic insulator meet.      c)  Machine Shop, on or about 3/13/15:  Bridgeport milling machine was not equipped with a guard to cover the chuck and tool.    d)  Ceramic Lab, on or about 3/12/15:  Schold mixer was not provided with guarding around the rotating shaft.       e)  Cement Mix Area, on or about 3/13/15:  Two cement mixers were not provided with adequate guarding around the rotating shafts.    Victor Insulators, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1904.32(a)(2), which was contained in OSHA inspection number 314352204, citation number 1, item number 3, and was affirmed as a final order on 8/08/2011, with respect to a workplace located at 280 Maple Ave., Victor, NY.
Recent events (2)
  • — I (R) $5040
  • — Z (R) $8400

1910.146 C02

Other-than-serious 2 instances 2 exposed
Issued
Jul 16, 2015
Abate by
Jul 26, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces:  a)  Filter Press Area, on or about 3/13/15:  (2) Two cisterns that were deemed as permit required confined spaces were not provided with danger signs to inform employees of the potential dangers posed by entering the spaces.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Victor Insulators, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340466762.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.