Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VICTOR INSULATORS INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of VICTOR INSULATORS INC. in 280 MAPLE AVE., VICTOR, NY 14564 (NAICS 327113). OSHA activity number 340664622.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Victor Insulators INC. — free Get an email when a new federal OSHA severe-injury report for Victor Insulators INC. is published. One employer, no account, unsubscribe in one click.
Site address
280 MAPLE AVE.
City
VICTOR
State
NY
ZIP
14564
Mailing
280 MAPLE AVENUE, VICTOR, NY 14564
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327113
Employees
100
Ownership type
A

2 citations on file for this inspection.

1910.1000 C

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 24, 2015
Abate by
Oct 29, 2015
Penalty
Initial $3,500 · Current $2,275 Reduced

Hazardous substances 9010

29 CFR 1910.1000(c): Employees were exposed to materials in excess of the eight hour permissible exposure limit, listed in Table Z-3 of subpart Z of 29 CFR part 1910:    a)  Rail Car Area, on or about 7/24/15, an employee working as a Bulk Material Handler was exposed at a level of 1.83 milligrams per cubic meter (mg/m3) of airborne silica, over an eight hour time weighted average (TWA), approximately 2.74 times the OSHA permissible exposure limit of .667 mg/m3. The sampling period was for 345 minutes. A zero increment is included for the 135 minutes not sampled. Employee was wearing a North half mask air purifying respirator.
Recent events (2)
  • — I (S) $2275
  • — Z (S) $3500

1910.1000 E

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 24, 2015
Abate by
Oct 27, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): Please enter your variable information after this comment box.    a) Rail Car Area, on or about 7/24/15: Feasible administrative or engineering controls were not implemented to reduce employee exposure to silica below the OSHA Permissible Exposure Limit. Employee exposures as referenced in Citation 1 Item 1a      EFFECTIVE MEANS OF ABATEMENT INCLUDE BUT ARE NOT LIMITED TO:   1. Provide improved local exhaust ventilation at point of operation   2. Provide an attached exhaust to individual pneumatic air spade   3. Train employees on methods to avoid unnecessary exposure   4. Continue with the respiratory protection program.   5. Conduct air monitoring after any changes have been made to determine if improvements have been made.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Victor Insulators INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340664622.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.