MILTON, FL —
OSHA Inspection: CENTRAL WIRE INDUSTRIES, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CENTRAL WIRE INDUSTRIES, LLC in 5881 COMMERCE ROAD, MILTON, FL 32583 (NAICS 332618). OSHA activity number 340468743.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CENTRAL WIRE INDUSTRIES, LLC
- Site address
- 5881 COMMERCE ROAD
- City
- MILTON
- State
- FL
- ZIP
- 32583
- Mailing
- 5881 COMMERCE ROAD, MILTON, FL 32583
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332618
- Employees
- 34
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.212 A01
- Issued
- Aug 24, 2015
- Abate by
- Apr 8, 2016
- Penalty
- Initial $2,380 · Current $875 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about March 17, 2015, in the Production area, at the #902 Niehoff model 110A5 wire draw machine, the wire drawing drive shaft and wire spooling guide pulleys were not guarded to prevent the entry of arms and hands into the ingoing nip points and rotating parts, exposing employees to caught-in and amputation hazards. b. On or about March 17, 2015, in the Production area, at the #903 Niehoff model 110A5 wire draw machine, the wire drawing drive shaft and wire spooling guide pulleys were not guarded to prevent the entry of arms and hands into the ingoing nip points and rotating parts, exposing employees to caught-in and amputation hazards. c. On or about March 17, 2015, in the Production area, at the #922 wire draw machine, the wire drawing drive shaft and wire spooling guide pulleys were not guarded to prevent the entry of arms and hands into the ingoing nip points and rotating parts, exposing employees to caught-in and amputation hazards. d. On or about March 17, 2015, in the Production area, at the #923 wire draw machine, the wire drawing drive shaft and wire spooling guide pulleys were not guarded to prevent the entry of arms and hands into the ingoing nip points and rotating parts, exposing employees to caught-in and amputation hazards. e. On or about March 17, 2015, in the Production area, at the #929 wire draw machine, the wire drawing drive shaft and wire spooling guide pulleys were not guarded to prevent the entry of arms and hands into the ingoing nip points and rotating parts, exposing employees to caught-in and amputation hazards. f. On or about March 17, 2015, in the Production area, at the #900 Laribee wire draw machine, the wire drawing drive shaft and wire spooling guide pulleys were not guarded to prevent the entry of arms and hands into the ingoing nip points and rotating parts, exposing employees to caught-in and amputation hazards. g. On or about March 17, 2015, in the Production area, at the #920 wire draw machine, the wire drawing drive shaft and wire spooling guide pulleys were not guarded to prevent the entry of arms and hands into the ingoing nip points and rotating parts, exposing employees to caught-in and amputation hazards. h. On or about March 17, 2015, in the Production area, at the #2 and #3 Re-reel machines, the drive and spooling guide pulleys were not guarded to prevent the entry of arms and hands into the ingoing nip points and rotating parts, exposing employees to caught-in and amputation hazards.
Recent events (2)
- — I (S) $875
- — Z (S) $2380
1910.219 C02 I
- Issued
- Aug 24, 2015
- Abate by
- Apr 8, 2016
- Penalty
- Initial $2,975 · Current $875 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a. On or about March 17, 2015, in the Production area, at the #62 wire draw machine, a horizontal driveshaft was not protected by stationary casing(s), by trough(s) or enclosed sides and exposed employees to caught-in hazards. b. On or about March 17, 2015, in the Production area, at the #1 re-reel machine, a horizontal driveshaft from the electric motor to the drive gearbox was not protected by stationary casing(s), by trough(s) or enclosed sides and exposed employees to caught-in hazards.
Recent events (2)
- — I (S) $875
- — Z (S) $2975
1910.219 C04 I
- Issued
- Aug 24, 2015
- Abate by
- Apr 8, 2016
- Penalty
- Initial $2,380 · Current $875 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a. On or about March 17, 2015, in the Production area, at the #904 wire draw machine, a projecting horizontal shaft, not guarded by nonrotating caps, was used to drive wire take up reels, did not present a smooth edge and end and projected more than one half the diameter of the shaft, exposing employees to caught-in hazards. b. On or about March 17, 2015, in the Production area, at the #924 wire draw machine, a projecting horizontal shaft, not guarded by nonrotating caps, was used to drive wire take up reels, did not present a smooth edge and end and projected more than one half the diameter of the shaft, exposing employees to caught-in hazards. c. On or about March 17, 2015, in the Production area, at the #925 wire draw machine, a projecting horizontal shaft, not guarded by nonrotating caps, was used to drive wire take up reels, did not present a smooth edge and end and projected more than one half the diameter of the shaft, exposing employees to caught-in hazards.
Recent events (2)
- — I (S) $875
- — Z (S) $2380
1910.219 C04 II
- Issued
- Aug 24, 2015
- Abate by
- Apr 8, 2016
- Penalty
- Initial $2,380 · Current $875 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered: a. On or about March 17, 2015, in the Production area, at the #79 Bartell twelve-wire, six-inch reel wire stranding machine projecting horizontal shaft, used to intake wire, had a keyway which was not filled or covered up exposing employees to caught-in hazards. b. On or about March 17, 2015, in the Production area, at the #76 Bartell twelve-wire, six-inch reel wire stranding machine projecting horizontal shaft, used to intake wire, had a keyway which was not filled or covered up exposing employees to caught-in hazards.
Recent events (2)
- — I (S) $875
- — Z (S) $2380
1910.219 D01
- Issued
- Aug 24, 2015
- Abate by
- Apr 8, 2016
- Penalty
- Initial $2,380 · Current $875 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a. On or about March 17, 2015, in the Production area, at the #904 wire draw machine, a single pulley located on the back of the machine was not guarded and exposed employees to caught-in hazards. b. On or about March 17, 2015, in the Production area, at the #79 Bartell twelve-wire, six-inch reel wire stranding machine, the electric driver motor pulley located under the machine was not guarded and exposed employees to caught-in hazards. c. On or about March 17, 2015, in the Production area, at the #34 National Standard Bartell twelve-wire, six-inch reel wire stranding machine take-up reel had a drive pulley that was not fully guarded and exposed employees to caught-in hazards. d. On or about March 17, 2015, in the Production area, at the #74 Watson twelve-wire, six-inch reel wire stranding machine, a single pulley, driven by a two inch flat horizontal belt, located on the wire spool take-up reel, was not fully enclosed by a guard and exposed employees to caught-in hazards. e. On or about March 17, 2015, in the Production area, at the #309 National Standard Bartell seven-wire, ten-inch reel wire stranding machine take-up reel had a drive pulley that was not fully guarded and exposed employees to caught-in hazards. f. On or about March 17, 2015, in the Production area, at the #32 Bartell twelve-wire, ten-inch reel wire stranding machine, dual capstan pulleys were not fully guarded and exposed employees to caught-in hazards. g. On or about March 17, 2015, in the Production area, at the #33 National Standard Bartell nineteen-wire, ten-inch reel wire stranding machine, dual capstan pulleys were not fully guarded and exposed employees to caught-in hazards. h. On or about March 17, 2015, in the Production area, at the #309 National Standard Bartell seven-wire, ten-inch reel wire stranding machine, dual capstan pulleys were not fully guarded and exposed employees to caught-in hazards. i. On or about March 17, 2015, in the Production area, at the #310 Bartell seven-wire, ten-inch reel wire stranding machine, dual capstan pulleys were not fully guarded and exposed employees to caught-in hazards. j. On or about March 17, 2015, in the Production area, at the #312 Bartell seven-wire, ten-inch reel wire stranding machine, dual capstan pulleys were not fully guarded and exposed employees to caught-in hazards. k. On or about March 17, 2015, in the Production area, at the #102, #105, #106, #107, #117, #118, #110, #112, #114, #115, #116, #108 and #109 six-inch reel, wire stranding machine, take-up reel had drive pulleys that were not fully guarded and exposed employees to caught-in hazards. l. On or about March 17, 2015, in the Production area, at the #102, #105, #117, #118, #110, #112, #114, #115, #116, #104 and #103 six-inch reel, wire stranding machine, dual capstan pulleys were not fully guarded and exposed employees to caught-in hazards. m. On or about March 17, 2015, in the Production area, at the #62 Watson wire stranding machine, dual capstan pulleys were not fully guarded and exposed employees to caught-in hazards. n. On or about March 17, 2015, in the Production area, at the #30 twelve-wire stranding machine, dual capstan pulleys, were not fully guarded and exposed employees to caught-in hazards. o. On or about March 17, 2015, in the Production area, at the #30 twelve-wire stranding machine, take-up reel pulleys, were not fully guarded and exposed employees to caught-in hazards. p. On or about March 17, 2015, in the Production area, at the #1 Re-reel machine, the take-up reel drive idler pulley, was not fully guarded and exposed employees to caught-in hazards. q. On or about March 17, 2015, in the Production area, at the #4 Re-reel machine, dual capstan pulleys were not fully guarded and exposed employees to caught-in hazards. r. On or about March 17, 2015, in the Production area, at the #4 Re-reel machine take-up reel, there were seven pulleys not fully guarded and exposed employees to caught-in hazards. s. On or about March 17, 2015, in the Production area, at the #5 Re-reel machine, dual capstan pulleys were not fully guarded and exposed employees to caught-in hazards. t. On or about March 17, 2015, in the Production area, at the #5 Re-reel machine take-up reel, there was a single pulley not fully guarded and exposed employees to caught-in hazards. u. On or about March 17, 2015, in the Production area, at the #6 Re-reel machine, dual capstan pulleys were not fully guarded and exposed employees to caught-in hazards. v. On or about March 17, 2015, in the Production area, at the #6 Re-reel machine take-up reel, there were two pulleys that were not fully guarded and exposed employees to caught-in hazards.
Recent events (2)
- — I (S) $875
- — Z (S) $2380
1910.219 E01 I
- Issued
- Aug 24, 2015
- Abate by
- Apr 8, 2016
- Penalty
- Initial $2,380 · Current $875 Reduced
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): a. On or about March 17, 2015, in the Production area, at the #904 wire draw machine, a single 1/2 inch horizontal V-belt, located on the back of the machine, was not fully enclosed by a guard and exposed employees to caught-in and amputation hazards. b. On or about March 17, 2015, in the Production area, at the #34 National Standard Bartell twelve-wire, six-inch reel wire stranding machine, a single 1/2 inch V-shaped horizontal belt, located on the wire spool take-up reel, was not fully enclosed by a guard and exposed employees to caught-in hazards. c. On or about March 17, 2015, in the Production area, at the #74 Watson twelve-wire, six-inch reel wire stranding machine, a single two inch flat horizontal belt, located on the wire spool take-up reel, was not fully enclosed by a guard and exposed employees to caught-in hazards. d. On or about March 17, 2015, in the Production area, at the #309 National Standard Bartell seven-wire, ten-inch reel wire stranding machine, a single 1/2 inch horizontal V-belt, located on the wire spool take-up reel, was not fully enclosed by a guard and exposed employees to caught-in hazards. e. On or about March 17, 2015, in the Production area, at the #30 wire stranding machine, a single a single two-inch flat horizontal belt, located on the wire spool take-up reel which was not fully enclosed by a guard and exposed employees to caught-in hazards. f. On or about March 17, 2015, in the Production area, at the #4 Re-reel machine, there were two (2) two-inch flat horizontal belts used to drive the wire spool take-up reel, were not fully enclosed by a guard and exposed employees to caught-in hazards. g. On or about March 17, 2015, in the Production area, at the #5 Re-reel machine, there was a single flat horizontal belt used to drive the wire spool take-up reel that was not fully enclosed by a guard and exposed employees to caught-in hazards.
Recent events (2)
- — I (S) $875
- — Z (S) $2380
1910.219 E03 I
- Issued
- Aug 24, 2015
- Abate by
- Apr 8, 2016
- Penalty
- Initial $2,380 · Current $875 Reduced
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a. On or about March 17, 2015, in the Production area, at the #79 Bartell twelve-wire, six-inch reel wire stranding machine, the electric driver motor pulley located under the machine had two 1/2 inch V-shaped vertical belts that were not enclosed by a guard and exposed employees to caught-in hazards. b. On or about March 17, 2015, in the Production area, at the wire spool take-up reel for the#79 Bartell twelve-wire, six-inch reel wire stranding machine take-up reel had a round belt on the drive pulleys that was not enclosed by a guard and exposed employees to caught-in hazards. c. On or about March 17, 2015, in the Production area, at the wire spool take-up reel for the#78 Bartell twelve-wire, six-inch reel wire stranding machine take-up reel had a round belt on the drive pulleys that was not enclosed by a guard and exposed employees to caught-in hazards. d. On or about March 17, 2015, in the Production area, at the wire spool take-up reel for the#77 National Standard Bartell twelve-wire, six-inch reel wire stranding machine take-up reel had a round belt on the drive pulleys that was not enclosed by a guard and exposed employees to caught-in hazards. e. On or about March 17, 2015, in the Production area, at the wire spool take-up reel for the #102, #105, #106, #107, #117, #118, #110, #112, #114, #115, #116, #108, #109, #104 and #103 six-inch reel, wire stranding machine, take-up reel had belts on the drive pulleys that were not enclosed by a guard and exposed employees to caught-in hazards. f. On or about March 17, 2015, in the Production area, at the wire spool take-up reel for the #30 wire stranding machine take-up reel had a round belt on the drive pulleys that was not enclosed by a guard and exposed employees to caught-in hazards. g. On or about March 17, 2015, in the Production area, at the wire spool take-up reel for the #1 Re-reel machine, a flat belt on the drive pulleys that was not enclosed by a guard and exposed employees to caught-in hazards. h. On or about March 17, 2015, in the Production area, at the wire spool take-up reel for the #4 Re-reel machine, had three round belts on the drive pulleys that were not enclosed by a guard and exposed employees to caught-in hazards. i. On or about March 17, 2015, in the Production area, at the wire spool take-up reel for the #5 Re-reel machine, had a single round belt on the drive pulleys that was not enclosed by a guard and exposed employees to caught-in hazards. j. On or about March 17, 2015, in the Production area, at the wire spool take-up reel for the #6 Re-reel machine, had a single round belt on the drive pulleys that was not enclosed by a guard and exposed employees to caught-in hazards.
Recent events (2)
- — I (S) $875
- — Z (S) $2380
1910.219 F01
- Issued
- Aug 24, 2015
- Abate by
- Apr 8, 2016
- Penalty
- Initial $2,380 · Current $875 Reduced
General-duty citation text
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): a. On or about March 17, 2015, in the Production area, at the #79 Bartell twelve-wire, six-inch reel wire stranding machine, the wire spool take up reel located at the end of the machine had two six-inch gears that were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii) and exposed employees to caught-in hazards. b. On or about March 17, 2015, in the Production area, at the #78 Bartell twelve-wire, six-inch reel wire stranding machine, the wire spool take up reel located at the end of the machine had two six-inch gears that were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii) and exposed employees to caught-in hazards. c. On or about March 17, 2015, in the Production area, at the #77 National Standard Bartell twelve-wire, six-inch reel wire stranding machine, the wire spool take up reel located at the end of the machine had two six-inch gears that were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii) and exposed employees to caught-in hazards. d. On or about March 17, 2015, in the Production area, at the #76 Bartell twelve-wire, six-inch reel wire stranding machine, the wire spool take up reel located at the end of the machine had two six-inch gears that were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii) and exposed employees to caught-in hazards. e. On or about March 17, 2015, in the Production area, at the #74 Watson twelve-wire, six-inch reel wire stranding machine, the wire spool take up reel located at the end of the machine had two gears that were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii) and exposed employees to caught-in hazards. f. On or about March 17, 2015, in the Production area, at the #102, #105, #106, #107, #117, #118, #110, #112, #114, #115, #116, #108 and #109 six-inch reel wire stranding machines, the wire spool take up reel located at the end of the machines had gears that were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii) and exposed employees to caught-in hazards. g. On or about March 17, 2015, in the Production area, at the #2 and #3 Re-reel machines, the wire spool take up reel located at the end of the machine had two gears that were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii) and exposed employees to caught-in hazards. h. On or about March 17, 2015, in the Production area, at the #4 Re-reel machine, the wire spool take up reel located at the end of the machine had three gears that were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii) and exposed employees to caught-in hazards. i. On or about March 17, 2015, in the Production area, at the #5 Re-reel machine, the wire spool take up reel located at the end of the machine had two gears that were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii) and exposed employees to caught-in hazards.
Recent events (2)
- — I (S) $875
- — Z (S) $2380
1910.219 F03
- Issued
- Aug 24, 2015
- Abate by
- Apr 8, 2016
- Penalty
- Initial $2,380 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: a. On or about March 17, 2015, in the Production areas, at the #902 Niehoff model 110A5 wire draw machine, sprocket wheels and a chain were not enclosed and exposed employees to caught-in hazards. b. On or about March 17, 2015, in the Production areas, at the #903 Niehoff model 110A5 wire draw machine, sprocket wheels and a chain were not enclosed and exposed employees to caught-in hazards. c. On or about March 17, 2015, in the Production areas, at the wire spool take-up reel for the #74 Watson 12-wire, 6-inch reel wire stranding machine, sprocket wheels and a chain were not enclosed and exposed employees to caught-in hazards. d. On or about March 17, 2015, in the Production areas, at the wire spool take-up reel for the #307 Bartell 6 or 10-inch reel wire stranding machine, sprocket wheels and a chain were not enclosed and exposed employees to caught-in hazards. e. On or about March 17, 2015, in the Production areas, at the wire spool take-up reel for the #6 Re-reel machine, sprocket wheels and a chain were not enclosed and exposed employees to caught-in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $2380
1910.132 D02
- Issued
- Aug 24, 2015
- Abate by
- Oct 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2): a. On or about March 17, 2015, Plant-wide - The personal protective equipment requirements for job tasks related to machine, forklift and crane operations were not certified by the employer to identify the proper personal protective equipment used to protect employees from exposure to struck-by, caught-in and noise hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 I
- Issued
- Aug 24, 2015
- Abate by
- Oct 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a. On or about March 17, 2015, Plant Wide - The employer did not conduct an annual or more frequent inspection of the facility's energy control procedure to ensure that it was properly implemented during the repair and service work on equipment, to include but not limited to; wire stranding machines, wire drawing machines, re-reeling machines, an over-head crane and forklifts, exposing employees to struck-by, caught-in, crushing, and electrical shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H03 IV
- Issued
- Aug 24, 2015
- Abate by
- Dec 1, 2015
- Penalty
- Initial $595 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: a. On or about March 17, 2015, wire stranding employees used hazardous chemicals such as, but not limited to denatured alcohol, lacquer thinner, stains, greases, lubricants and compressed gases while working in the plant production room and the employer did not provide an explanation of the new labeling system and safety data sheet.
Recent events (2)
- — I (O) $0
- — Z (O) $595
More inspections at Central Wire Industries, LLC