OSHA Inspection: CENTRAL WIRE INDUSTRIES, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CENTRAL WIRE INDUSTRIES, LLC in 5881 COMMERCE ROAD, MILTON, FL 32583 (NAICS 332618). OSHA activity number 340491778.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Central Wire Industries, LLC — free Get an email when a new federal OSHA severe-injury report for Central Wire Industries, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5881 COMMERCE ROAD
City
MILTON
State
FL
ZIP
32583
Mailing
5881 COMMERCE ROAD, MILTON, FL 32583
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
33
Ownership type
A

1 citation on file for this inspection.

1910.95 C01

Serious Gravity 5 5 instances 9 exposed
Issued
May 13, 2015
Abate by
Jun 30, 2015
Penalty
Initial $3,500 · Current $2,100 Reduced

Hazardous substances 81108111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:  a.  A machine operator, working in the 12 wire area, was exposed to a noise dose of 178.2%, or an equivalent dBA of 94.1 dBA, which was capable of causing permanent hearing loss. The sampling was performed for 439 minutes during one shift on March 26, 2015.  The employer did not have a continuing, effective hearing conservation program.    b.  A machine operator, working in the small 7 wire area, was exposed to a noise dose of 174.3%, or an equivalent dBA of 94.0 dBA, which was capable of causing permanent hearing loss. The sampling was performed for 437 minutes during one shift on March 26, 2015.  The employer did not have a continuing, effective hearing conservation program.    c.  A machine operator, working with the Watson Brand Stranding Machine #62, was exposed to a noise dose of 146.2%, or an equivalent dBA of 92.7 dBA, which was capable of causing permanent hearing loss. The sampling was performed for 435 minutes during one shift on March 26, 2015.  The employer did not have a continuing, effective hearing conservation program.    d.  A machine operator, working in the 30, 307, and 311 area, was exposed to a noise dose of 96.58%, or an equivalent dBA of 89.7 dBA, which was capable of causing permanent hearing loss. The sampling was performed for 440 minutes during one shift on March 26, 2015.  The employer did not have a continuing, effective hearing conservation program.    e.  A machine operator, working in the Dry Draw 907 area, was exposed to a noise dose of 85.94%, or an equivalent dBA of 88.9 dBA, which was capable of causing permanent hearing loss. The sampling was performed for 423 minutes during one shift on March 26, 2015.  The employer did not have a continuing, effective hearing conservation program.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500