JACKSON, MO —
OSHA Inspection: WAHLCO-D.W. TOOL INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WAHLCO-D.W. TOOL INC. in 5830 STATE HIGHWAY V, JACKSON, MO 63755 (NAICS 423930). OSHA activity number 340484286.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WAHLCO-D.W. TOOL INC.
- Site address
- 5830 STATE HIGHWAY V
- City
- JACKSON
- State
- MO
- ZIP
- 63755
- Mailing
- 5830 STATE HIGHWAY V, JACKSON, MO 63755
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 26
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.147 C06 I
- Issued
- Aug 17, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $3,850 · Current $1,579 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a/ The energy control procedure(s) for machinery such as but not limited to the Wysong Shear, m/n 1025, s/n P37-647, were not inspected throughout 2014. This shear utilizes 480 volts, 80 p.s.i. pneumatic, and gravity to operate.
Recent events (2)
- — I (S) $1578.5
- — Z (S) $3850
1910.147 D02
- Issued
- Aug 17, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $5,390 · Current $2,210 Reduced
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a/ Inside of the Reclaim Department, on or about 03/19/15, the 480 volt electrical disconnect belonging to the Tumbler Rotary Valve, unknown make, model, or serial number, was not turned off prior to an employee reaching in to clear a jam. This employee suffered from multiple amputations of his fingers.
Recent events (2)
- — I (S) $2209.9
- — Z (S) $5390
1910.147 D03
- Issued
- Aug 17, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s). a/ Inside of the Reclaim Department, on or about 03/19/15, the 480 volt electrical disconnect belonging to the Tumbler Rotary Valve, unknown make, model, or serial number, was not operated prior to an employee reaching in to clear a jam. This employee suffered from multiple amputations of his fingers.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Aug 17, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a/ Inside of the Reclaim Department, on or about 03/19/15, a padlock or other suitable device was not applied to the 480 volt electrical disconnect belonging to the Tumbler Rotary Valve, unknown make, model, or serial number, prior to an employee reaching in to clear a jam. This employee suffered from multiple amputations of his fingers.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A04
- Issued
- Aug 17, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $5,390 · Current $2,210 Reduced
General-duty citation text
29 CFR 1910.212(a)(4): Revolving drums, barrels, and containers were not guarded by an enclosure which was interlocked with the drive mechanism, so that the barrel, drum, or container cannot revolve unless the guard enclosure was in place: a/ Inside of the Reclaim Department, the drum belonging to the Tumbler Rotary Machine, unknown make, model, or serial number, was unguarded.
Recent events (2)
- — I (S) $2209.9
- — Z (S) $5390
1910.304 G05
- Issued
- Aug 17, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $3,850 · Current $1,579 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a/ Inside of the Staging Area, the flexible cord attached to a Toro Leaf Blower, m/n 51618, s/n 31400J100, was missing its grounding pin.
Recent events (2)
- — I (S) $1578.5
- — Z (S) $3850
1910.334 A02 II
- Issued
- Aug 17, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made: a/ Inside of the Staging Area, the grounding pin belonging to a flexible cord that was attached to a Toro Leaf Blower, m/n 51618, s/n 31400J100, was missing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.332 B01
- Issued
- Aug 17, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $3,850 · Current $1,579 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: a/ Inside of the Reclaim Department, the employer failed to provide adequate instruction to employee(s) in safety-related work practices while working with testing equipment around live conductors belonging to the American Baler, m/n PAC4029-830, s/n 9327. This baler was electrically powered by 480 volts and 50 amperes.
Recent events (2)
- — I (S) $1578.5
- — Z (S) $3850
1910.333 C02
- Issued
- Aug 17, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(c)(2): The employer did not ensure that only qualified persons were working on energized circuits and that qualified persons were familiar with the proper use of special precautionary techniques, personal protective equipment (PPE), insulating and shielding materials, and insulated tools: a/ Inside of the Reclaim Department, the employer authorized "unqualified" employee(s) to work with testing equipment around live conductors belonging to the American Baler, m/n PAC4029-830, s/n 9327. The "unqualified" employee(s) were unable to identify any special precautionary techniques, the minimum level of PPE required, or for the need for insulating or shielding materials to include tools. This baler was electrically powered by 480 volts and 50 amperes.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.335 A01 I
- Issued
- Aug 17, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: a/ Inside of the Reclaim Department, employee(s) were not provided with adequate personal protective equipment for the arms, eyes, face, legs, and torso while working with testing equipment around live conductors belonging to the American Baler, m/n PAC4029-830, s/n 9327. This baler was electrically powered by 480 volts and 50 amperes.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Aug 17, 2015
- Abate by
- Oct 2, 2015
- Penalty
- Initial $26,950 · Current $10,940 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: a/ Inside of the Fabrication Shop, the Burr King Vertical Sander, m/n 760, unknown s/n, was unguarded. Wahlco-D.W. Tool Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 948684, citation number 2, item number 2, and was affirmed as a final order on 12/14/13, with respect to a workplace located at 5830 State Highway V, Jackson, MO 63755. Wahlco-D.W. Toll Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 315172791, citation number 1, item number 2a, and was affirmed as a final order on 02/23/11, with respect to a workplace located at 5830 State Highway V, Jackson, MO 63755.
Recent events (2)
- — I (R) $10939.7
- — Z (R) $26950
More inspections at Wahlco-D.W. Tool INC.
View Wahlco-D.W. Tool INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340484286.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.