Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INTEPLAST GROUP, LTD.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of INTEPLAST GROUP, LTD. in 101 INTEPLAST BLVD, LOLITA, TX 77971 (NAICS 326111). OSHA activity number 340508357.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Inteplast Group, LTD. — free Get an email when a new federal OSHA severe-injury report for Inteplast Group, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
101 INTEPLAST BLVD
City
LOLITA
State
TX
ZIP
77971
Mailing
P.O. BOX 405, LOLITA, TX 77971
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326111
Employees
2000
Ownership type
A

7 citations on file for this inspection.

1910.219 D01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jun 4, 2015
Abate by
Jun 10, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  At line #47 in the Celuka Plant, employees were receiving product from the extruder and stacking it flush once it dropped off the conveyer line. At the point where the conveyer ends and the product stacks employees are exposed to the pinch/caught-in hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.219 F01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jun 4, 2015
Abate by
Jun 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(1): Gears. Gears shall be guarded in accordance with one of the following methods: (f)(1)(i) By a complete enclosure; or (f)(1)(ii) By a standard guard as described in paragraph (o) of this section, at least seven (7) feet high extending six (6) inches above the mesh point of the gears; or  f)(1)(iii)  By a band guard covering the face of gear and having flanges extended inward beyond the root of the teeth on the exposed side or sides. Where any portion of the train of gears guarded by a band guard is less than six (6) feet from the floor a disk guard or a complete enclosure to the height of six (6) feet shall be required.    At line #47 in the Celuka Plant, gears were not guarded as required. Employees were receiving product from the extruder and stacking it flush once it dropped off the conveyer line. At the point where the conveyer ends and the product stacks employees are exposed to the pinch/caught-in hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 II

Serious Gravity 5 1 instance 7 exposed
Issued
Jun 4, 2015
Abate by
Jun 10, 2015
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:    At the Celuka Plant, employees are exposed to hazards related to unsecured, welding gas, cylinders. The employees were exposed to struck-by hazards in Celuka section of the Plant, where employees and members of manage walk-by to access the extrusion lines and other work zones.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.303 F02

Serious Gravity 5 1 instance 7 exposed
Issued
Jun 4, 2015
Abate by
Jun 10, 2015
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    On March 12, 2015 and times prior there to, at the Celuka area of the plant, at Cabinet LP-3 employees were exposed to hazards as each disconnecting means or overcurrent device was not marked, located or arranged so the purpose was evident.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.305 B01 I

Serious Gravity 5 1 instance 7 exposed
Issued
Jun 4, 2015
Abate by
Jun 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:  On March 12, 2015 and times prior there to, at the Celuka area of the plant, at the pillar support structure near the Cabinet LP-3, where conduit runs into electric cabinets EF-PP5,  employees were exposed to possible electrocution where unused openings on the conduit fittings were not effectively closed, exposing live, flexible electrical cords.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 7 exposed
Issued
Jun 4, 2015
Abate by
Jun 10, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  On March 12, 2015 and times prior there to, at the Celuka area of the plant, at Cabinet LP-3 employees were exposed to possible electrocution where unused openings on the panel inside the cabinet were not effectively closed. The cabinet was energized at 480voltz.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 10 1 instance 6 exposed
Issued
Jun 4, 2015
Abate by
Jun 10, 2015
Penalty
Initial $7,000 · Current $3,000 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to the joints or terminal screws:    On March 12, 2015 and times prior there to, at line #47 employees were working doing maintenance on machinery that did not have proper strain relief on a flexible cord. The cord was energized at 480voltz.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $7000

View Inteplast Group, LTD.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340508357.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.