BARRIGADA, GU —
OSHA Inspection: S.P.E. (GUAM), INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of S.P.E. (GUAM), INC. in LEON GUERRERO STREET, BARRIGADA, GU 96913 (NAICS 531120). OSHA activity number 340519768.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S.P.E. (GUAM), INC.
- Site address
- LEON GUERRERO STREET
- City
- BARRIGADA
- State
- GU
- ZIP
- 96913
- Mailing
- P.O. BOX 8364, TAMUNING, GU 96931
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 531120
- Employees
- 20
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.23 D01
- Issued
- Jul 17, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails. (a) In The Warehouse Building, the S.P.E. (Guam) Inc. failed to provide standard stair railings (not more than 34 inches nor less than 30 inches), exposing employees to possible fall-related injuries.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.157 C01
- Issued
- Jul 17, 2015
- Abate by
- Jul 24, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): The employer did not mount portable fire extinguishers so that they were readily accessible to employees without subjecting the employees to possible injury. (a) In The Warehouse Building, the S.P.E. (Guam) Inc. did not mount two portable 20 LB Multi-Purpose Dry Chemical fire extinguishers.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 G02
- Issued
- Jul 17, 2015
- Abate by
- Aug 12, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(2): The employer did not provide the educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: (a) In The Warehouse Building: S.P.E. (Guam) Inc. did not provide an educational program at least annually for all employees on the use of portable fire extinguishers and the hazards associated with incipient stage fire fighting, exposing employees to possible hazards of smoke inhalation and/or burns.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at S.P.E. (Guam), INC.
View S.P.E. (Guam), INC.'s full OSHA safety record →
More inspections in this industry (NAICS 531120)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340519768.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.