OSHA Inspection: ANGEL OF THE WINDS CASINO & HOTEL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ANGEL OF THE WINDS CASINO & HOTEL in 3438 STOLUCKQUAMISH LANE, ARLINGTON, WA 98223 (NAICS 713210). OSHA activity number 340528785.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Angel of the Winds Casino & Hotel — free Get an email when a new federal OSHA severe-injury report for Angel of the Winds Casino & Hotel is published. One employer, no account, unsubscribe in one click.
Site address
3438 STOLUCKQUAMISH LANE
City
ARLINGTON
State
WA
ZIP
98223
Mailing
3438 STOLUCKQUAMISH LANE, ARLINGTON, WA 98223
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
713210
Employees
527
Ownership type
A

14 citations on file for this inspection.

1910.101 B

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 28, 2015
Penalty
Initial $1,721 · Current $861 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:  a)       Warehouse;  Four compressed gas cylinders of Argon and Nitrogen were stored unsecured against the stairway wall.
Recent events (2)
  • — I (S) $860.5
  • — Z (S) $1721

1910.213 S06

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 28, 2015
Penalty
Initial $2,295 · Current $1,148 Reduced
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards:  a)       Warehouse;  On or about April 7, 2015, there was saw dust on the floor and the DeWalt miter saw and stand that was used during the weekend of April 4th and 5th 2015.
Recent events (2)
  • — I (S) $1147.5
  • — Z (S) $2295

1910.215 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 28, 2015
Penalty
Initial $2,869 · Current $1,435 Reduced
29 CFR 1910.215(a)(1): Abrasive wheel(s) used on grinding machinery were not used with safety guard(s):  a)      Warehouse;  A Task Force grinder (serial no. 064403) was not equipped with tongue guards.
Recent events (2)
  • — I (S) $1434.5
  • — Z (S) $2869

1910.215 A04

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  a)  Warehouse;  A Task Force grinder (serial no. 064403) had its tool rest approximately 3/8 inch away from the grinding stone.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I D

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 28, 2015
Penalty
Initial $1,721 · Current $861 Reduced
29 CFR 1910.303(g)(2)(i)(D): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by elevation of 2.44 m (8.0 ft) or more above the floor or other working surface:  a)  Warehouse Small Parts Area;  A florescent light bulb was located 7 feet 9 inches from the floor and it was not guarded.
Recent events (2)
  • — I (S) $860.5
  • — Z (S) $1721

1910.305 B02 I

Serious Gravity 1 15 instances 5 exposed
Issued
Apr 28, 2015
Penalty
Initial $1,721 · Current $861 Reduced
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  a)       Warehouse, wall adjacent to stairway;  A junction box with exposed live wiring did not have a cover.
Recent events (2)
  • — I (S) $860.5
  • — Z (S) $1721

1910.22 D01

Other-than-serious 2 instances 5 exposed
Issued
Apr 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate:  a)  Warehouse;  The second floor mezzanine storage area which was located over office and kitchen space was not load rated. It stored items including but not limited to:  outdoor umbrellas, rolled up flooring material and spools of cable.   b)  Warehouse:  The small locked storage room located on the second floor mezzanine storage area had boxes of batteries stored above the workspace and it was not load rated.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 2 instances 10 exposed
Issued
Apr 28, 2015
Abate by
May 31, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  a)      Room 105 Housekeeping Closet:  The JL Industries fire extinguisher was not visually inspected monthly.  b)      Water Treatment Plant:  The Amerex fire extinguisher was not visually inspected monthly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E03

Other-than-serious 2 instances 10 exposed
Issued
Apr 28, 2015
Abate by
May 31, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a)  Watershed Kitchen, Three fire extinguishers on both sides of the deep fryers and stove top cooking area had their last annual inspection in January of 2014. They include an Amerex fire extinguisher, an Ansul-K Guard fire extinguisher and Buckeye fire extinguisher.   b)  Shipping and Receiving Area;  The Amerex fire extinguisher had its last annual inspection in January 2014.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.159 C10

Other-than-serious 1 instance 10 exposed
Issued
Apr 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.159(c)(10): The minimum vertical clearance of 18 inches between automatic sprinkler systems sprinklers and the material below was not maintained:  a)  Watershed Kitchen Walk-In Freezer:  There were white containers of frozen strawberries stored 7 inches from the sprinkler head.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 5 exposed
Issued
Apr 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)  Warehouse;  An office type of relocatable power tap (power strip) was used to power DeWalt battery chargers in a dusty shop type of environment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 5 exposed
Issued
Apr 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a)  Hotel Laundry Storage Room;  A large cardboard box was stored underneath the breaker panel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 5 exposed
Issued
Apr 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a)       Warehouse Cubicle:  A green extension cord was used to power a desk lamp.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.334 A02 I

Other-than-serious 2 instances 4 exposed
Issued
Apr 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a)      Katies Kitchen;  A RF Hunter Grease Sucker has its cord pulled from the strain relief, exposing insulated wires.   b)      Hotel Laundry Room:  An orange extension cord was pulled from its strain relief.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Angel of the Winds Casino & Hotel's full OSHA safety record →