WARRINGTON, PA —
OSHA Inspection: HIGH QUALITY BUILDERS, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of HIGH QUALITY BUILDERS, INC. in WARRINGTON POINT ADMIRAL LANE, UNIT 19 THRU 22, WARRINGTON, PA 18976 (NAICS 238130). OSHA activity number 340603372.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HIGH QUALITY BUILDERS, INC.
- Site address
- WARRINGTON POINT ADMIRAL LANE, UNIT 19 THRU 22
- City
- WARRINGTON
- State
- PA
- ZIP
- 18976
- Mailing
- 907 WOODLANE ROAD APT. 62B, BEVERLY, NJ 08010
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.28 A
- Issued
- Jul 15, 2015
- Penalty
- Initial $1,760 · Current $1,760
General-duty citation text
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions: a) Construction site, Unit 19 through 22 - On or about April 27, 2015, employees using pneumatic framing nail guns did not wear eye protection to prevent injury.
Recent events (1)
- — Z (S) $1760
1926.150 C01 VI
- Issued
- Jul 15, 2015
- Penalty
- Initial $1,760 · Current $1,760
General-duty citation text
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite: a) Construction site, Unit 19 through 22 - On or about April 27, 2015, a charged fire extinguisher was not provided within 50 feet of a five gallon can of gasoline used for fueling a portable generator.
Recent events (1)
- — Z (S) $1760
1926.416 E01
- Issued
- Jul 15, 2015
- Penalty
- Initial $1,320 · Current $1,320
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Construction site, Unit 19 through 22 - On or about April 27, 2015, employees used an extension cord with multiple areas of damage to the sheathing that exposed the individual wires to damage that could result in an electric shock.
Recent events (1)
- — Z (S) $1320
1926.1053 B04
- Issued
- Jul 15, 2015
- Penalty
- Initial $1,760 · Current $1,760
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Construction site, Unit 19 through 22 - On or about April 27, 2015, an employee framing the unit worked from a portable A-frame (step) ladder that was leaned against the corner of a stud.
Recent events (1)
- — Z (S) $1760
1926.1053 B13
- Issued
- Jul 15, 2015
- Penalty
- Initial $1,760 · Current $1,760
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) Construction site, Unit 19 through 22 - On or about April 27, 2015, an employee framing the unit worked from the top step of a portable A-frame (step) ladder, exposing him to a potential fall.
Recent events (1)
- — Z (S) $1760
1926.501 B13
- Issued
- Jul 15, 2015
- Abate by
- Jul 27, 2015
- Penalty
- Initial $5,280 · Current $5,280
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Construction site, Unit 19 through 22 - On or about April 27, 2015, an employee framing the unit walked/worked from the top plate of the wall, exposing him to a fall hazard greater than 6 feet. High Quality Builders, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1016561, citation number 01, item number 01, and was affirmed as a final order on 03/30/2015, with respect to a workplace located at 7 Herbert Avepeahala Park, Long Beach Township, NJ 08008.
Recent events (1)
- — Z (R) $5280
More inspections at High Quality Builders, INC.
View High Quality Builders, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in PA
Source