Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. FOREST SERVICE-PRESCOTT NATIONAL FOREST

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of U.S. FOREST SERVICE-PRESCOTT NATIONAL FOREST in VERDE RANGER DISTRICT 300 EAST HWY. 260, CAMP VERDE, AZ 86322 (NAICS 924120). OSHA activity number 340616382.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Forest Service-Prescott National Forest — free Get an email when a new federal OSHA severe-injury report for U.S. Forest Service-Prescott National Forest is published. One employer, no account, unsubscribe in one click.
Site address
VERDE RANGER DISTRICT 300 EAST HWY. 260
City
CAMP VERDE
State
AZ
ZIP
86322
Mailing
2971 WILLOW CREEK ROAD, BLDG. 4, PRESCOTT, AZ 86301
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
10
Ownership type
D

12 citations on file for this inspection.

1910.106 D02 I

Serious Gravity 1 1 instance 6 exposed
Issued
Oct 23, 2015
Abate by
Nov 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.106(d)(2)(i): Approved containers and/or portable tanks were not used for the storage of flammable liquids:   (a) Verde Ranger District, engine bay-flammable storage cabinet: On or about May 6, 2015 and at times prior thereto, gasoline was stored in dolmar-style containers. These two-compartment fuel/oil propylene containers, which comply with standard specification ASTM F 852, are not approved under the Nationally Recognized Testing Laboratory (NRTL) program since ASTM F 852 is not a recognized test standard under the NRTL program. In addition, the storage area was not provided with a fire detection system capable of detecting incipient stage fires.
Recent events (1)
  • — Z (S) $0

1910.159 C02

Serious Gravity 1 1 instance 8 exposed
Issued
Oct 23, 2015
Abate by
Nov 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.159(c)(2): The employer did not properly maintain the installed automatic sprinkler system:  a) Verde Ranger District, shop: On or about May 6, 2015 and at times prior thereto, the employer did not assure that a main drain flow test was performed annually on the installed fire sprinkler system or that the inspector's test valve was opened every two years to ensure that the system operated properly. The last inspection on the system was conducted June 2010.
Recent events (1)
  • — Z (S) $0

1910.165 D04

Serious Gravity 1 1 instance 10 exposed
Issued
Oct 23, 2015
Abate by
Nov 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.165(d)(4): All supervised employee alarm systems were not tested at least annually for reliability and adequacy:  (a) Verde Ranger District: On or about May 6, 2015 and at times prior thereto, the IntelliKnight 5808 fire alarm control/communicator system was last tested June 2010
Recent events (1)
  • — Z (S) $0

1910.165 E

Serious Gravity 1 1 instance 8 exposed
Issued
Oct 23, 2015
Abate by
Nov 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.165(e): Manually operated actuation devices for use in conjunction with employee alarms were not unobstructed, conspicuous and readily accessible:  a) Verde Ranger District, mechanical room: On or about May 6, 2015 and at times prior thereto, the manual fire alarm pull station was blocked by a step ladder and ceiling tile.  b) Verde Ranger District, warehouse/ready room: On or about May 6, 2015 and at times prior thereto, the manual fire alarm pull station was blocked by exercise equipment.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 1 instance 4 exposed
Issued
Oct 23, 2015
Abate by
Nov 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Verde Ranger District, shop: On or about May 6, 2015 and at times prior thereto, the rotating chuck of the drill press was not guarded.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 1 1 instance 4 exposed
Issued
Oct 23, 2015
Abate by
Nov 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  (a) Verde Ranger District, shop: On or about May 6, 2015 and at times prior thereto, the work rest/abrasive wheel opening was approximately 1-1/4 inch on the Black & Decker 6816 bench grinder.
Recent events (1)
  • — Z (S) $0

1910.36 G02

Other-than-serious 1 instance 4 exposed
Issued
Oct 23, 2015
Abate by
Nov 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  (a) Verde Ranger District, file room: On or about May 6, 2015 and at times prior thereto, exit access was obstructed by a table which reduced the exit access width to 24-1/2 inches.
Recent events (1)
  • — Z (O) $0

1910.37 B01

Other-than-serious 1 instance 6 exposed
Issued
Oct 23, 2015
Abate by
Nov 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that employees with normal vision could see along the exit route:    a) Verde Ranger District, conference room: On or about May 6, 2015 and at times prior thereto, the emergency light did not work.
Recent events (1)
  • — Z (O) $0

1910.101 B

Other-than-serious 1 instance 4 exposed
Issued
Oct 23, 2015
Abate by
Nov 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): Section 3.4.4, Compressed Gas Association Pamphlet P-1-1965, as adopted by 29 CFR 1910.101(b): Compressed gas cylinder(s) not in use were not properly supported to prevent them from being knocked over:  (a) Verde Ranger District, shop: On or about May 6, 2015 and at times prior thereto, a cylinder of compressed helium gas was not secured to prevent it from being knocked over.
Recent events (1)
  • — Z (O) $0

1910.157 E03

Other-than-serious 1 instance 8 exposed
Issued
Oct 23, 2015
Abate by
Nov 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  (a) Verde Ranger District, N/W corner: On or about May 6, 2015 and at times prior thereto, an annual maintenance check on the portable fire extinguisher was not conducted. The last annual maintenance check was conducted July 2012.
Recent events (1)
  • — Z (O) $0

1910.303 F02

Other-than-serious 1 instance 6 exposed
Issued
Oct 23, 2015
Abate by
Nov 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.  (a) Verde Ranger District, mechanical room: On or about May 6, 2015 and at times prior thereto, the circuit directory in breaker panel MDP was not current. Circuit modifications were not identified as to their purpose.
Recent events (1)
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 4 exposed
Issued
Oct 23, 2015
Abate by
Nov 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  (a) Verde Ranger District, shop: On or about May 6, 2015 and at times prior thereto, the flexible cord which supplied power to the table saw was connected to a plug without strain relief being provided.
Recent events (1)
  • — Z (O) $0

View U.S. Forest Service-Prescott National Forest's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340616382.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.