Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUMMIT DESIGN + BUILD, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUMMIT DESIGN + BUILD, LLC in 1323 S MICHIGAN AVE, CHICAGO, IL 60605 (NAICS 236220). OSHA activity number 340627512.

Watch Summit Design + Build, LLC — free Get an email when a new federal OSHA severe-injury report for Summit Design + Build, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1323 S MICHIGAN AVE
City
CHICAGO
State
IL
ZIP
60605
Mailing
1032 W. FULTON MARKET - SUITE 300, CHICAGO, IL 60607
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.405 A02 II B

Other-than-serious 1 instance 20 exposed
Issued
Penalty
Initial $1320.00 · Current $1000.00 Reduced
29 CFR 1926.405(a)(2)(ii)(B): Branch circuits shall originate in a power outlet or panelboard. Conductors shall be run as multiconductor cord or cable assemblies or open conductors, or shall be run in raceways. All conductors shall be protected by overcurrent devices at their ampacity. Runs of open conductors shall be located where the conductors will not be subject to physical damage, and the conductors shall be fastened at intervals not exceeding 10 feet (3.05 m). No branch-circuit conductors shall be laid on the floor. Each branch circuit that supplies receptacles or fixed equipment shall contain a separate equipment grounding conductor if the branch circuit is run as open conductors.    a.  On or about May 13, 2015 - at the above addressed jobsite, the electric cables/wiring were not protected from damage when exiting the temporary power panels in the basement, and floors 1 through 7, thereby exposing the employees and subcontractor employees to hazards associated with electrical shock.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $1320

1926.405 B01

Other-than-serious 1 instance 20 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(b)(1): Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.    a.  On or about May 13, 2015 - at the above addressed jobsite, on the 7th and 5th floors, unused openings in electrical boxes were not effectively closed, thereby exposing the employees and subcontractor employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.1052 C01 I

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $1320.00 · Current $1000.00 Reduced
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with at least one handrail.    a.  On or about May 13, 2015 - at the above addressed jobsite, the stairway leading to the basement did not have a handrail, thereby exposing employees and subcontractor employees to fall hazards.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $1320

View SUMMIT DESIGN + BUILD, LLC's full OSHA safety record →