OSHKOSH, WI —
OSHA Inspection: OSHKOSH COIL SPRING, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of OSHKOSH COIL SPRING, INC in 3575 N. MAIN ST., OSHKOSH, WI 54901 (NAICS 332612). OSHA activity number 340628254.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OSHKOSH COIL SPRING, INC
- Site address
- 3575 N. MAIN ST.
- City
- OSHKOSH
- State
- WI
- ZIP
- 54901
- Mailing
- 3575 N. MAIN, OSHKOSH, WI 54901
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332612
- Employees
- 132
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 1, 2015
- Abate by
- Jul 16, 2015
- Penalty
- Initial $6,300 · Current $4,410 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Oshkosh Coil Spring facility at 2575 N. Main St. Oshkosh, WI: On and before 4/30/15, employees operating spring forming machines were exposed to amputation hazards at the point of operation between the parts and the dies.
Recent events (2)
- — I (S) $4410
- — Z (S) $6300
1910.212 A02
- Issued
- Jul 1, 2015
- Abate by
- Jul 16, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(2): Machine guard(s) on machine(s) were so installed that they offered accident hazards in themselves: Oshkosh Coil Spring facility at 3575 N. Main St. Oshkosh, WI: On and before 5/14/15, the Diacro bending machine had a guard on the top of the die that created a pinch point during the operating cycle which exposed employees to amputation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Oshkosh Coil Spring, INC
View Oshkosh Coil Spring, INC's full OSHA safety record →
More inspections in this industry (NAICS 332612)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340628254.