OSHKOSH, WI —
OSHA Inspection: OSHKOSH COIL SPRING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of OSHKOSH COIL SPRING, INC. in 3575 N. MAIN ST., OSHKOSH, WI 54901 (NAICS 332612). OSHA activity number 341392942.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OSHKOSH COIL SPRING, INC.
- Site address
- 3575 N. MAIN ST.
- City
- OSHKOSH
- State
- WI
- ZIP
- 54901
- Mailing
- 3575 N. MAIN, OSHKOSH, WI 54901
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332612
- Employees
- 120
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- May 13, 2016
- Abate by
- Aug 11, 2016
- Penalty
- Initial $6,930 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about April 7, 2016, employees performing set-up activities on the PC-8 machine were not required to utilize energy control procedures to prevent employee exposure to hazardous energy from the movement of machine components. The employer had not developed and implemented energy control procedures to ensure that throughout the machine set-up activity including machine adjustments, employees were protected from hazardous energy.
Recent events (2)
- — I (S) $4000
- — Z (S) $6930
1910.147 D
- Issued
- May 13, 2016
- Abate by
- Aug 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) On or about April 7, 2016 employees were exposed to machine hazards associated with moving parts and pinch points when they engaged in set-up activities on the PC-8 machine. The employer did not ensure that employees implemented energy control application steps prior to allowing them work past the physical machine guards to install and adjust tooling and machine axis. The machine was not deenergized prior to the employee engaging in the servicing/maintenance activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Oshkosh Coil Spring, INC.
View Oshkosh Coil Spring, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332612)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341392942.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.