Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: NEWMARK MEDICAL COMPONENTS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NEWMARK MEDICAL COMPONENTS, INC. in 2670 SOUTH MAIN STREET, WATERBURY, CT 06706 (NAICS 334510). OSHA activity number 340634260.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Newmark Medical Components, INC. for free Get an email when a new federal OSHA severe-injury report for Newmark Medical Components, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2670 SOUTH MAIN STREET
City
WATERBURY
State
CT
ZIP
06706
Mailing
2670 SOUTH MAIN STREET, WATERBURY, CT 06706
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334510
Employees
14
Ownership type
Private (A)

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 2 instances 2 exposed
Issued
Jun 24, 2015
Penalty
Initial $3,600 · Current $2,520 Reduced
29 CFR 1910.212(a)(1): Point of Operation Guarding. Point of operation is the area on a machine where work is actually performed upon the material being processed. The point of operation of machines whose operation exposes an employee to injury, shall be guarded:  WORKSHOP:  The points of the operation of the following Perkins eyelet presses were not guarded:      1.  Perkins eyelet press #9.  ABATED DURING THE INSPECTION      2.  Perkins eyelet press #13. ABATED DURING THE INSPECTION
Recent events (2)
  • · I (S) $2520
  • · Z (S) $3600

1910.217 C01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 24, 2015
Penalty
Initial $4,500 · Current $3,150 Reduced
29 CFR 1910.217(c)(1)(i): It shall be the responsibility of the employer to provide and insure the usage of "point of operation guards" or properly applied and adjusted point of operation devices on every operation performed on a mechanical power press. See Table O-10.  WORKSHOP: The point-of operation of the Federal 22-ton progressive mechanical power press was unguarded.    ABATED DURING THE INSPECTION
Recent events (2)
  • · I (S) $3150
  • · Z (S) $4500

1910.219 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 24, 2015
Penalty
Initial $3,600 · Current $2,520 Reduced
29 CFR 1910.219(b)(1): Flywheels. Flywheels located so that any part is seven (7) feet or less above floor or platform shall be guarded in accordance with the requirements of this subparagraph:  (i)  With an enclosure of sheet, perforated, or expanded metal, or woven wire;  WORKSHOP:  The flywheel of the Federal progressive mechanical power press was partially unguarded.    ABATED DURING THE INSPECTION
Recent events (2)
  • · I (S) $2520
  • · Z (S) $3600

View Newmark Medical Components, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340634260.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.