Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NHVS INTERNATIONAL INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of NHVS INTERNATIONAL INC. in 7600 TYLER BLVD., MENTOR, OH 44060 (NAICS 333517). OSHA activity number 340756345.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nhvs International INC. — free Get an email when a new federal OSHA severe-injury report for Nhvs International INC. is published. One employer, no account, unsubscribe in one click.
Site address
7600 TYLER BLVD.
City
MENTOR
State
OH
ZIP
44060
Mailing
7600 TYLER BLVD., MENTOR, OH 44060
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333517
Employees
400
Ownership type
A

5 citations on file for this inspection.

1910.95 B01

Serious Gravity 5 1 instance 75 exposed
Issued
Sep 15, 2015
Abate by
Dec 31, 2015
Penalty
Initial $5,000 · Current $3,000 Reduced

Hazardous substances 8110

29 CFR 1910.95(b)(1): When employees were subjected to sound exceeding those listed in Table G-16, feasible administrative or engineering controls were not utilized:    On or about August 3, 2015, a dosimeter (sn: ESN070249) was placed on an employee working in the Mentor grinding area for a total of 442 minutes. The employee was exposed to noise at 187.7% of the permissible daily noise exposure level, with an equivalent time-weighted average sound level of 94.5 dBA. Exposure calculations include a zero increment for the 38 minutes not sampled.       On or about August 3, 2015, a dosimeter (sn: ESN070250) was placed on an employee working in the Mentor grinding area for a total of 441 minutes. The employee was exposed to noise at 204.1% of the permissible daily noise exposure level, with an equivalent time-weighted average sound level of 95.1 dBA. Exposure calculations include a zero increment for the 39 minutes not sampled.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5000

1910.147 C06 II

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 15, 2015
Abate by
Oct 3, 2015
Penalty
Initial $4,000 · Current $2,400 Reduced
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:    On or about August 3, 2015, periodic inspections had not been performed when energy control procedures were utilized for equipment such as the wax injection machines.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4000

1910.147 C07 IV

Serious Gravity 5 1 instance 398 exposed
Issued
Sep 15, 2015
Abate by
Oct 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training on the energy control program had been accomplished and kept up to date:  On or about August 3, 2015, employees that work in areas where lockout may be utilized had not received documented training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.1 A02

Other-than-serious 1 instance 400 exposed
Issued
Sep 15, 2015
Abate by
Oct 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1904.1(a)(2): The employer did not maintain OSHA injury and illness records:  On or about August 3, 2015, the OSHA Log of Work-Related Injuries and Illnesses (OSHA's Form 300) for 2012, 2013, and 2014 were not available upon request.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K06

Other-than-serious 1 instance 75 exposed
Issued
Sep 15, 2015
Abate by
Oct 3, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:   On or about August 3, 2015, employees permitted to wear dust masks were not provided with appendix D information.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Nhvs International INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340756345.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.