OSHA Inspection: ST. LOUIS COLD DRAWN, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ST. LOUIS COLD DRAWN, INC. in 1060 PERSHALL ROAD, SAINT LOUIS, MO 63137 (NAICS 331221). OSHA activity number 340774678.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ST. Louis Cold Drawn, INC. — free Get an email when a new federal OSHA severe-injury report for ST. Louis Cold Drawn, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1060 PERSHALL ROAD
City
SAINT LOUIS
State
MO
ZIP
63137
Mailing
1060 PERSHALL ROAD, SAINT LOUIS, MO 63137
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
160
Ownership type
A

45 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $6,930 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1):   Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employee(s) in that employee(s) were exposed to the hazard of being struck-by:  a/  The last periodic inspection of a P & H 5T Underslung Crane (DL-8 South) did not include a thorough examination of the suspension pins.  A suspension pin sheared off on or about July 02, 2015 resulting in the total collapse of the hoist and its suspended load.  One method of abatement to correct this apparent hazard is to inspect for loose or missing fasteners, such as bolts, nuts, pins, or rivets as required by ANSI B11.30-2010, paragraph 11-2.1.5.  DISCLAIMER:  a/  The employer is not limited to the abatement method(s) suggested by OSHA. b/  The employer is responsible for selecting and implementing an effective abatement method.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6930

1910.179 J03

Deleted Serious Gravity 10 11 instances 20 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(3):  A complete periodic inspection of crane(s) had not been conducted in the past 12 months:  Complete inspections of the following cranes were not performed:  a/ P & H 5T Overhead Crane a.k.a. KR North.  b/ P & H 5T Overhead Crane a.k.a. KR Center.  c/ P & H 5T Overhead Crane a.k.a. KR South.  d/ Demag 5T Overhead Crane a.k.a. SEC North.  e/ Demag 5T Overhead Crane a.k.a. SEC South.  f/ Demag 7T Overhead Crane a.k.a. DL20 North.   g/ P & H 5T Overhead Crane a.k.a. DL20 Center.  h/ P & H 5T Overhead Crane a.k.a. DL20 South.  i/ Demag 7T Overhead Crane a.k.a. DB West.  j/ P & H 7T Overhead Crane a.k.a. DB Center.  k/ P & H 7T Overhead Crane a.k.a. DB East.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 A03

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $4,950 · Current $0 Reduced
29 CFR 1910.22(a)(3): To facilitate cleaning, every floor, working place, and passageway were not kept free from protruding nails, splinters, holes, or loose boards:  a/  At the Danieli Line, the metal grating at the foot of the stairway leading over this machine was protruding approximately one half inch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4950

1910.37 A03

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit routes were not free and unobstructed:  a/  Inside of Building #2, specifically the Drawing Line Unit, the pedestrian exit route was partially obstructed by large pieces of steel supported by wooden dunnage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 C

Serious Gravity 5 1 instance 10 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $4,950 · Current $2,000 Reduced
29 CFR 1910.22(c):  Covers and/or guardrails were not provided to protect personnel from the hazards of open pits:    a/  Inside of Building #2, specifically along the west side of the gear box adjacent to a designated aisleway, an open pit that measured approximately 23"W X 17"D X 162"L was not provided with a cover and/or a standard guardrail system.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4950

1910.23 D01 III

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side:  a/  At the Kieserling Line, a flight of metal stairs four risers high was not equipped with stair railings along both open sides. The width of the tread was approximately 28 inches wide.  The fall distance into moving machine parts was approximately 38 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 E01

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(1): A standard railing did not consist of top rail, intermediate rail, and posts, and did not have a vertical height of 42 inches nominal from upper surface of top rail to floor, platform, runway, or ramp level:  a/  Inside of Building #2, specifically along the east side of the gear box adjacent to a designated aisleway, an open pit that measured approximately 23"W X 17"D X 62"L was provided with a standard guardrail system that was approximately five feet long.  The vertical height of the top rail was approximately 36 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 E02

Serious Gravity 5 1 instance 100 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(e)(2): A stair railing was not of construction similar to a standard railing but the vertical height was not more than 34 inches nor less than 30 inches from upper surface of top rail to surface of tread in line with face of riser at forward edge of tread:  a/  Inside of the Main Building, the flight of stairs consisting of 16 risers was equipped with a stair railing that was approximately 28 inches high.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.101 B

Serious Gravity 5 3 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $4,950 · Current $2,000 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:    a/  Adjacent to the Daneili Line, two compressed gas cylinders in storage marked as containing argon were not secured against falling.    b/  Adjacent to the Kieserling Line, specifically near the "Wheelabrator", one compressed gas cylinder in storage marked as containing oxygen was not secured against falling.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $4950

1910.253 B02 IV

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv):  Valve protection caps, wher cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  a/  At the compressed gas cylinder storage area adjacent to the Main Building, one compressed gas cylinder partially containing LPG was not equipped with a valve cap.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 I

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(i):  Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substances likely to cause or accelerate fire; or in an acetylene generator compartment:  a/  At the compressed gas cylinder storage area adjacent to the Main Building, one cylinder partially filled with oxygen was stored adjacent to acetylene cylinders.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.135 A01

Other-than-serious 2 instances 10 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $4,950 · Current $4,950
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects:    a/  At the Main Building, specifically at the Secondary Processing Area, which consisted of two loading docks at either side of the facility, protective helmets were not provided to employees who operate overhead cranes where the suspended load was at or above their heads.
Recent events (2)
  • — I (O) $4950
  • — Z (S) $4950

1910.147 C06 I

Deleted Serious Gravity 5 4 instances 5 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $4,950 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure(s) at least annually to ensure that the procedure and the requirements of this standard were being followed:  Periodic inspections of the following procedures were not performed:  a/  Kieserling Line.  b/  Schumag Line.  c/  Danieli Line.  d/  Draw Bench Line.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4950

1910.184 I01

Serious Gravity 10 1 instance 10 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $6,930 · Current $6,930
29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material:  a/  At the Danieli Line, specifically at the Pay-Off Area, a synthetic web sling used to move spools of rough raw steel product via an unmarked, overhead crane was equipped with an illegible tag.
Recent events (2)
  • — I (S) $6930
  • — Z (S) $6930

1910.184 I09

Serious Gravity 10 2 instances 10 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.184(i)(9): Synthetic web sling(s) were not immediately removed from service for having snags, cuts and tears:  a/  At the Danieli Line, specifically at the Pay-Off Area, a synthetic web sling used to move spools of rough raw steel product via an unmarked, overhead crane possessed a hole clear through the material.  b/  Inside of Building #2, the synthetic web sling used to move finished steel product via a Demag 7T Underhung Crane, s/n 79192, was badly ripped in multiple places.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 C02 I

Serious Gravity 10 7 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Jun 1, 2016
Penalty
Initial $6,930 · Current $6,930
29 CFR 1910.219(c)(2)(i):  Exposed part(s) of horizontal shafting were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    a/  Inside of the Secondary Building, specifically the Two Roll Straightener, a horizontal shaft approximately four feet above the floor was not guarded.    b/  Inside of the Main Building, specifically the Danieli Line, Two-Roll Section, a horizontal shaft approximately four feet above the floor was not guarded.    c/  Inside of the Main Building, specifically the Schumag Line, two, horizontal shafts approximately four feet above the floor were not guarded.    d/  Inside of the Main Building, specifically the Kieserling Line, two, horizontal shafts approximately four feet above the floor were not guarded.    e/  Inside of the Main Building, specifically the Kieserling Line, at the Two-Roller Station, a horizontal shaft approximately four feet above the floor was not guarded.
Recent events (2)
  • — I (S) $6930
  • — Z (S) $6930

1910.219 C03

Serious Gravity 10 1 instance 10 exposed
Issued
Dec 24, 2015
Abate by
Jun 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(3):  Vertical or inclined shafting was not enclosed with stationary casing(s):    a/  Inside of the Secondary Building, specifically the Two-Roll Straightener, an inclined shaft approximately four feet from the floor was unguarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E01 I

Serious Gravity 10 2 instances 10 exposed
Issued
Dec 24, 2015
Abate by
Jun 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i):  Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:    a/  Inside of Building #2, specifically along the designated aisleway of the Draw Bench Line, two, horizontal belts approximately 36 inches above the floor were unguarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 B

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $4,950 · Current $1,665 Reduced
29 CFR 1910.212(b):  Machines designed for a fixed location were not securely anchored to prevent walking or moving:    a/  Inside of the Machine Shop, the HDI Heavy-Duty Drill Press, m/n DP-56, s/n 251, was not anchored to the floor to prevent inadvertent movement.
Recent events (2)
  • — I (S) $1665
  • — Z (S) $4950

1910.215 A04

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $6,930 · Current $6,930
29 CFR 1910.215(a)(4):  Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch:  a/  Inside of the Maintenance Department, the work rest belonging to a Powermatic Pedestal Grinder, m/n 2100-25, s/n 511863, was approximately one inch away from the abrasive wheel.
Recent events (2)
  • — I (S) $6930
  • — Z (S) $6930

1910.215 B09

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9):  The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:  a/  Inside of the Maintenance Department, the tongue guard belonging to a Powermatic Pedestal Grinder, m/n 2100-25, s/n 511863, was approximately one inch away from the abrasive wheel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $4,950 · Current $4,950
29 CFR 1910.242(b):  Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.  a/  Inside of the Machine Shop, the compressed air used for cleaning purposes was set at a minimum of 60 p.s.i.
Recent events (2)
  • — I (S) $4950
  • — Z (S) $4950

1910.252 A02 VII

Other-than-serious 4 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $6,930 · Current $6,930
29 CFR 1910.252(a)(2)(vii):  Where practicable, all combustibles were not relocated at least 35 feet (10.7 m) from the work site. Where relocation was impracticable, combustibles were not protected with flameproofed covers or otherwise shielded with metal or asbestos guards or curtains:    a/  At the Kieserling Line, combustibles were not relocated or suitably covered whenever arc welding or oxy-fuel cutting work was performed in the aisleways where large quantities of combustible liquids were present.  These combustible liquids consisted primarily of NRG AW Hydraulic Fluid, Exxon Petroleum Metalworking Fluid, Anticorit RP 4107 HCL, and Masterdraw.    b/  At the Schumag Line, combustibles were not relocated or suitably covered whenever arc welding or oxy-fuel cutting work was performed in the aisleways where large quantities of combustible liquids were present.  These combustible liquids consisted primarily of NRG AW Hydraulic Fluid, Exxon Petroleum Metalworking Fluid, Anticorit RP 4107 HCL, and Masterdraw.    c/  At the Danieli Line, combustibles were not relocated or suitably covered whenever whenever arc welding or oxy-fuel cutting work was performed in the aisleways where large quantities of combustible liquids were present.  These combustible liquids consisted primarily of NRG AW Hydraulic Fluid, Exxon Petroleum Metalworking Fluid, Anticorit RP 4107 HCL, and Masterdraw.  A fire broke out on or about August 11, 2015 at an area of this production line called the Tester Area.    d/  At Building #2, combustibles were not relocated or suitably covered at the Draw Bench Line whenever arc welding or oxy-fuel cutting work was performed in the aisleways where large quantities of combustible liquids were present.  These combustible liquids consisted primarily of NRG AW Hydraulic Fluid, Exxon Petroleum Metalworking Fluid, Anticorit RP 4107 HCL, and Masterdraw.
Recent events (2)
  • — I (O) $6930
  • — Z (S) $6930

1910.303 B01 II

Serious Gravity 10 2 instances 5 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $6,930 · Current $6,930
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:  a/  At the Kieserling Line, adjacent to the Collecting Bucket, the conduit supplying 240 volt electrical power to the Crouse Hinds Heavy-Duty Safety Switch, m/n 4, s/n HV362, had physically separated exposing the internal wiring.  b/  At the Kieserling Line, the conduit supplying electrical power to a component of this machine had physically separated exposing the internal wiring.
Recent events (2)
  • — I (S) $6930
  • — Z (S) $6930

1910.303 B05

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(5):  The overcurrent protective devices were not selected and coordinated to permit the circuit protective devices used to clear a fault to do so without the occurrence of extensive damage to the electrical components of the circuit:  a/  Inside of Building #2, a live circuit breaker was taped in the "open" position.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 C03 I

Other-than-serious 5 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $6,930 · Current $6,930
29 CFR 1910.303(c)(3)(i): All splices and joints and the free ends of the conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.      a/  At the Kieserling Line, an orange, flexible cord was spliced together without brazing, welding, or soldering with a fusible metal or alloy.  The splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.    b/  At the Schumag Line, a flexible cord was spliced together without brazing, welding, or soldering with a fusible metal or alloy.  The splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.  This flexible cord was located between two sections of metal flooring.    c/  At the Schumag Line, a flexible cord was spliced together without brazing, welding, or soldering with a fusible metal or alloy.  The splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.  This flexible cord was located on the metal grating running paralell to the line.      d/ At the Schumag line, a flexible cord was spliced together without brazing, welding, or soldering with a fusible metal or alloy.  The splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of conductors or with an insulating device identified for the purpose.  This flexible cord was used to power a Makita Sander, m/n 9031, unknown s/n.     e/  At Building #2, specifically the rear aisleway, an orange flexible cord was spliced together without brazing, welding, or soldering with a fusible metal or alloy.  The splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.  This flexible cord was powering a floor mounted fan.
Recent events (2)
  • — I (O) $6930
  • — Z (S) $6930

1910.305 G02 II

Deleted Serious Gravity 10 5 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  a/  At the Kieserling Line, an orange, flexible cord was spliced together without brazing, welding, or soldering with a fusible metal or alloy.  The splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.  b/  At the Schumag Line, a flexible cord was spliced together without brazing, welding, or soldering with a fusible metal or alloy.  The splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.  This flexible cord was located between two sections of metal flooring.  c/  At the Schumag Line, a flexible cord was spliced together without brazing, welding, or soldering with a fusible metal or alloy.  The splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.  This flexible cord was located on the metal grating running paralell to the line.    d/ At the Schumag line, a flexible cord was spliced together without brazing, welding, or soldering with a fusible metal or alloy.  The splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of conductors or with an insulating device identified for the purpose.  This flexible cord was used to power a Makita Sander, m/n 9031, unknown s/n.   e/  At Building #2, specifically the rear aisleway, an orange flexible cord was spliced together without brazing, welding, or soldering with a fusible metal or alloy.  The splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.  This flexible cord was powering a floor mounted fan.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 I B

Deleted Serious Gravity 10 2 instances 1 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $6,930 · Current $0 Reduced
29 CFR 1910.303(g)(1)(i)(B): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater :  a/  Inside of Building #2, specifically along the rear aisleway of the Draw Bench Line, objects including, but not limited to, a wooden bench and 55-gallon drums were located in the designated aisleway which ran parallel to the 480 volt distribution panel boxes.  These objects were generally 20 inches away from the panel boxes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6930

1910.303 G01 II

Serious Gravity 10 5 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  a/  Inside of Building #2, specifically along the rear aisleway of the Draw Bench Line, objects including, but not limited to, a wooden bench and 55-gallon drums were stored in the designated aisleway which ran parallel to the 480 volt distribution panel boxes.  These objects were generally 20 inches away from the panel boxes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 I

Serious Gravity 10 1 instance 20 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $6,930 · Current $6,930
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed:  a/  At the Kieserling Line, a flexible cord entering a motor unit was subjected to abrasion due to the vibration caused by moving machine parts throughout the line.  The opening through which this flexible cord entered was not effectively closed.
Recent events (2)
  • — I (S) $6930
  • — Z (S) $6930

1910.305 G01 IV A

Deleted Serious Gravity 10 2 instances 10 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $6,930 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a/  Inside of Building #2, specifically the Draw Bench Line, on 09/09/15 and 10/07/15, flexible cord sets (extension cords) ran under a hand washing basin.  These cord sets were used to supply power to a heating device and served as a substitute for fixed wiring.  b/  Inside of the Main Building, specifically the locker room, a Type SO flexible cord was used to power a permanently mounted electric hair dryer.  This flexible cord was used as a substitute for permanent wiring.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6930

1910.305 G01 IV B

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:  a/  Inside of the Main Building, a Type SO Flexible Cord was used to power a permanently mounted electric hand dryer.  This cord ran through the wall.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV D

Serious Gravity 10 3 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D):  Flexible cords and cables were used for purposes prohibited by subparagraphs (a) through (e) of this paragraph:      b/  Inside of the Main Building, an orange, flexible cord was attached to building surfaces as it ran its way to the roof.    c/  Inside of the Main Building, specifically in front of the Danieli Line, an orange, flexible cord was attached to building surfaces as it ran its way above the garage door.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F06

Other-than-serious 8 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $4,950 · Current $2,000 Reduced
29 CFR 1910.1200(f)(6):  The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with either the identification of its contents or hazard warning:    a/  At the Schumag Line, specifically the main aisleway, a dip tank partially filled with what was believed to be Regular Mineral Spirits was not labeled.    b/  At the Schumag Line, specifically the rear aisleway, a 55-gallon drum partially filled with what was believed to be Petroleum Metalworking Fluid was not labeled.    c/  At the Schumag Line, specifically the rear aisleway, a 55-gallon drum partially filled with what was believed to be a rust preventative was not labeled.    d/  Inside of Building #2, Draw Bench Line, specifically the rear aisleway, four, 55-gallon drums partially filled with what was believed to be a variety of lubricants were unlabeled.    e/  Inside of the Secondary Building, specifically in the aisleway, a black, plastic container partially filled with what was believed to be a rust preventative was not labeled.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $4950

1910.22 A02

Serious Gravity 10 5 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Jun 1, 2016
Penalty
Initial $69,300 · Current $4,620 Reduced
29 CFR 1910.22(a)(2): Where wet processes were used, drainage was not maintained, and false floors, platforms, mats, or other dry standing places were not provided when practicable:    a/ At the Kieserling Line, large quantities of of dust composed of Steel Shot Grit and Special Bar Quality were mixed with Anticorit RP 4107 HCL, a liquid rust preventer, and located along the "Wheelabrator" and the designated aisleways in general.  A variety of other lubricants were also present on the designated aisleways paralleling this line making walking extremely difficult.    b/  At the Schumag Line, large quantities of of dust composed of Steel Shot Grit and Special Bar Quality were mixed with Anticorit RP 4107 HCL, a liquid rust preventer, and located along the "Wheelabrator" and the designated aisleways in general.  A variety of other lubricants were also present on the designated aisleways paralleling this line making walking extremely difficult.    c/  At the Danieli Line, large quantities of of dust composed of Steel Shot Grit and Special Bar Quality were mixed with Anticorit RP 4107 HCL, a liquid rust preventer, and located along the "Wheelabrator" and the designated aisleways in general.  A variety of other lubricants were also present on the designated aisleways paralleling this line making walking extremely difficult.    d/  At Building #2, large quantities of of dust composed of Steel Shot Grit and Special Bar Quality were mixed with Anticorit RP 4107 HCL, a liquid rust preventer, and located along the "Wheelabrator" and the designated aisleways in general.  A variety of other lubricants were also present on the designated aisleways paralleling the Drawing Unit Line making walking extremely difficult.    e/  At the Twenty Ton Line, large quantities of of dust composed of Steel Shot Grit and Special Bar Quality were mixed with Anticorit RP 4107 HCL, a liquid rust preventer, and located along the "Wheelabrator" and the designated aisleways in general.
Recent events (2)
  • — I (S) $4620
  • — Z (W) $69300

1910.212 A01

Serious Gravity 10 50 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Oct 1, 2016
Penalty
Initial $69,300 · Current $1,000 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Inside of the Main Building, the two, vertical, rotating feeders providing rough raw steel product to the following production machines were not guarded:    a/  Kieserling Line.    b/  Schumag Line.    c/  Danieli Line.    Inside of the Main Building, the reciprocating machine parts at various locations throughout the lengths of the following production machines where the operators and other employees work were inadequately guarded or not at all:    a/  Kieserling Line.    b/  Schumag Line.    c/  Danieli Line.    Inside of the Main Building, the in-running nip points at various locations throughout the lengths of the following production machines where the operators and other employees work were inadequately guarded or not at all:    a/  Kieserling Line.    b/  Schumag Line.    c/  Danieli Line.    Inside Building #2, specifically at the base of the "Wheelabrator" the rotating parts of the following machine were unguarded:    a/  Auger.    Inside of the Tool & Die Room, the rotating parts belonging to the following machines were not guarded:    a/  Die Quip Lathe, m/n DQB66, s/n B06-223.    b/  Schuer Speed Lathe, m/n LAZB, s/n 40674M.    c/  Schuer Speed Lathe, unknown m/n or s/n.    Inside of the Machine Shop, the rotating parts belonging to the following machines were not guarded:    a/  JET Manual Lathe, s/n GH-1460ZX.    b/  HDI Heavy-Duty Drill Press, m/n DP-56, s/n 251.    c/  Kalamazoo Horizontal Band Saw, m/n H9AW, s/n 8865.    d/  OOYA Radial Arm Drill, m/n RE-1225M, s/n 69-9543.    Inside of the Twenty Ton Line, two, vertical, rotating feeders providing rough raw steel product were unguarded.    Inside of the Twenty Ton Line, the robotic arm feeding rough raw steel product into this production line was inadequately guarded.    Inside of the Twenty Ton Line, five, vertical, in-running nip points were inadequately guarded.
Recent events (2)
  • — I (S) $1000
  • — Z (W) $69300

1910.212 A03 II

Deleted Repeat Gravity 10 1 instance 2 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $13,860 · Current $0 Reduced
29 CFR 1910.212(a)(3)(ii):  Point(s) of operation (P.O.O.) of machinery were not guarded to prevent employee(s) from having any part of their body in danger zone(s) during operating cycle(s):  a/  Inside of the Maintenance Department, the unguarded P.O.O. belonging to the Uni-Hydra Ironworker, m/n 5074, s/n 3PE322A, was approximately one inch wide.  The unguarded P.O.O. was the structural shear on this machine.   St. Louis Cold Drawn Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.219(e)(3)(i), which was contained in OSHA inspection number 908320, citation 1, item 7, and was affirmed as a final order on 09/10/14, with respect to a workplace located at 1060 Pershall Road, St. Louis, Missouri 63137.
Recent events (2)
  • — I (R) $0
  • — Z (R) $13860

1910.219 D01

Deleted Repeat Gravity 10 5 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $13,860 · Current $0 Reduced
29 CFR 1910.219(d)(1):  Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified at 29 CFR 1910.219(m) and (o):  a/  Inside of the Main Building, specifically at the Kieserling Line, two pulleys were unguarded.  The pulleys were approximately four feet above the floor.    b/  Inside of the Main Building, specifically at the Schumag Line, a pulley was partially unguarded.  The pulley was approximately five feet above the floor.  c/  Inside of the Main Building, specifically near the operator's station on the Danieli Line, a pulley was unguarded.  The pulley was approximately four feet above and adjacent to the designated walkway.   St. Louis Cold Drawn Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.219(d)(1), which was contained in OSHA inspection number 908320, citation 1, item 8a, and was affirmed as a final order on 09/10/14, with respect to a workplace located at 1060 Pershall Road, St. Louis, Missouri 63137.
Recent events (2)
  • — I (R) $0
  • — Z (R) $13860

1910.219 E03 I

Serious Gravity 10 3 instances 20 exposed
Issued
Dec 24, 2015
Abate by
Jun 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts were not enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section:    a/  At the Kieserling Line, two inclined belts were unguarded.  The maximum height of the pulleys was approximately 62 inches.    b/  At the Danieli Line, specifically adjacent to the operator's station, one inclined belt was unguarded.  The maximum height of the pulley was approximately 36 inches.    St. Louis Cold Drawn Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.219(e)(3)(i), which was contained in OSHA inspection number 908320, citation 1, item 8b, and was affirmed as a final order on 09/10/14, with respect to a workplace located at 1060 Pershall Road, St. Louis, Missouri 63137.
Recent events (2)
  • — I (S) $0
  • — Z (R) $0

1910.303 B07 IV

Deleted Repeat Gravity 10 2 instances 20 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $13,860 · Current $0 Reduced
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating:  a/  At the Schumag Line, specifically the rear aisleway, a live, quad-receptacle box possessed a damaged outlet.  A flexible cord was plugged into this box.  b/  At the Schumag Line, specifically the main aisleway, a live, quad-receptacle box possessed a knockout that was partially pushed in.  St. Louis Cold Drawn Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.303(b)(7)(iv), which was contained in OSHA inspection number 908320, citation 1, item 10, and was affirmed as a final order on 09/10/14, with respect to a workplace located at 1060 Pershall Road, St. Louis, Missouri 63137.
Recent events (2)
  • — I (R) $0
  • — Z (R) $13860

1910.304 G05

Deleted Repeat Gravity 10 1 instance 5 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $13,860 · Current $0 Reduced
29 CFR 1910.304(g)(5):  The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a/  Inside of Building #2, specifically at the Work Station, the flexible cord supplying 120 volt electrical power to the Milwaukee Portable Band Saw, m/n 6226, s/n 457HD14230136, was missing its grounding pin.  St. Louis Cold Drawn Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.304(g)(5), which was contained in OSHA inspection number 908320, citation 1, item 12, and was affirmed as a final order on 09/10/14, with respect to a workplace located at 1060 Pershall Road, St. Louis, Missouri 63137.
Recent events (2)
  • — I (R) $0
  • — Z (R) $13860

1910.305 B01 II

Serious Gravity 10 8 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $13,860 · Current $13,860
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:    a/  Inside of Building #2, an unused opening approximately two inches wide existed on the front panel of a 480 volt, fuse distribution panel box.    b/  Inside of Building #2, specifically in the Hot Water Heating Room, six circuit breakers were missing from a live, circuit breaker panel box.  The unused opening was covered in duct tape.     c/  Inside of the Main Building, specifically at the bottom of the main stairwell, a live, dual receptacle box was missing a knockout.    St. Louis Cold Drawn Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.305(b)(1)(ii), which was contained in OSHA inspection number 908320, citation 1, item 13a, and was affirmed as a final order on 09/10/14, with respect to a workplace located at 1060 Pershall Road, St. Louis, Missouri 63137.
Recent events (2)
  • — I (S) $13860
  • — Z (R) $13860

1910.305 B02 I

Serious Gravity 10 4 instances 30 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers identified for the purpose:    a/  At the Kieserling Line, the cover belonging to a live, junction box was held in place by one out of four screws.  The internal wiring was fully exposed to dust and liquids.    b/  Inside of Building #2, the cover belonging to a live, junction box was missing.  This junction box was located just above the floor of the rear aisleway of the Draw Bench Line.    c/  Inside of Building #2, the latches belonging to a cover to a live, 480 volt fuse distribution panel box were ineffective in keeping it closed.  The upper latch was severely damaged leaving an opening approximately four inches wide.  The lower latch was held in place by a piece of wire.    d/  Inside of Building #2, the cover belonging to a live, junction box attached to the Draw Bench Line was missing.    St. Louis Cold Drawn Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.305(b)(2)(i), which was contained in OSHA inspection number 908320, citation 1, item 13b, and was affirmed as a final order on 09/10/14, with respect to a workplace located at 1060 Pershall Road, St. Louis, Missouri 63137.
Recent events (2)
  • — I (S) $0
  • — Z (R) $0

1910.305 G02 II

Deleted Repeat Gravity 10 1 instance 5 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $13,860 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a/  At the Secondary Processing Area, the outer insulation belonging to a flexible cord attached to a pendant control for an unmarked, overhead crane was severely damaged.  One of two strain relief cables stemming from the pendant control to the flexible cord was snapped.  Strain relief was broken.  St. Louis Cold Drawn Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.219(e)(3)(i), which was contained in OSHA inspection number 908320, citation 1, item 14, and was affirmed as a final order on 09/10/14, with respect to a workplace located at 1060 Pershall Road, St. Louis, Missouri 63137.
Recent events (2)
  • — I (R) $0
  • — Z (R) $13860

1910.334 A02 II

Deleted Repeat Gravity 10 6 instances 20 exposed
Issued
Dec 24, 2015
Abate by
Feb 12, 2016
Penalty
Initial $13,860 · Current $0 Reduced
29 CFR 1910.334(a)(2)(ii):  When there was a defect or evidence of damage that might expose an employee to injury, the defective or damaged item shall be removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe had been made:  a/  At the Kieserling Line, a section of flexible cord stemming from a motor was missing approximately three inches of its outer insulation.  b/  At the Kieserling Line, a section of flexible cord stemming from a second motor was missing a portion of its outer insulation.  c/  In between the Kieserling and Schumag Lines, the outer insulation belonging to a yellow, flexible cord that powered an industrial shop vac, unknown make, model, or serial number, was nearly severed in half.   d/  At the Schumag Line, the outer insulation belonging to the flexible cord supplying 120 volt electrical power to an Industrial Shop Vac, unknown m/n or s/n, was missing.  e/  Inside of Building #2, specifically at the Work Station, the outer insulation belonging to the flexible cord supplying 120 volt electrical power to the Milwaukee Portable Band Saw, m/n 6226, s/n 457HD14230136, was missing.  f/  Inside of the Maintenance Department, the outer insulation belonging to a flexible cord powering a 220 volt Miller Plasma Cutter #74 was severely damaged.  The conductors were exposed.   St. Louis Cold Drawn Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.219(e)(3)(i), which was contained in OSHA inspection number 908320, citation 1, item 15, and was affirmed as a final order on 09/10/14, with respect to a workplace located at 1060 Pershall Road, St. Louis, Missouri 63137.
Recent events (2)
  • — I (R) $0
  • — Z (R) $13860

View ST. Louis Cold Drawn, INC.'s full OSHA safety record →