Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UMICORE SPECIALTY MATERIALS RECYCLING, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of UMICORE SPECIALTY MATERIALS RECYCLING, LLC in 28960 LAKELAND BLVD., WICKLIFFE, OH 44092 (NAICS 331492). OSHA activity number 340780204.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Umicore Specialty Materials Recycling, LLC — free Get an email when a new federal OSHA severe-injury report for Umicore Specialty Materials Recycling, LLC is published. One employer, no account, unsubscribe in one click.
Site address
28960 LAKELAND BLVD.
City
WICKLIFFE
State
OH
ZIP
44092
Mailing
28960 LAKELAND BLVD., WICKLIFFE, OH 44092
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331492
Employees
50
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 6, 2016
Abate by
Feb 29, 2016
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about June 30, 2015, the employer failed to ensure written procedures were utilized by employees who clean the strainer on the SA reactors.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.147 C04 II B

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 6, 2016
Abate by
Feb 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:     On or about July 14, 2015, the employer failed to ensure all hazardous energy sources (pneumatics) were identified in specific lockout procedures for employees who clean the strainer on the SA reactors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 6, 2016
Abate by
Feb 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    On or about July 14, 2014, the employer failed to ensure employees performing lockout tagout performed all steps while performing lockout/tagout on the SA Reactor such as but not limited to:     Employees were exposed to machine hazards associated with pressurized pneumatic energy. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], lockout/tagout device application [(d)(4)], dissipation of residual energy [(d)(5)(I)], and verification of isolation [(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 6, 2016
Abate by
Feb 29, 2016
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:     On or about July 14, 2015, the employer failed to ensure annual audits for the lockout procedures were performed and documented for employees who clean the strainer on the SA reactors.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

1910.147 C07 I A

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 6, 2016
Abate by
Feb 29, 2016
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:    On or about July 14, 2015, the employer failed to ensure authorized lockout/tagout training was accomplished for employees who clean the strainer on the SA reactors
Recent events (2)
  • — I (S) $4900
  • — Z (S) $7000

View Umicore Specialty Materials Recycling, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340780204.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.