Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUIS QUINDI

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LUIS QUINDI in 4 WEETAMO WAY, WESTFORD, MA 01886 (NAICS 238160). OSHA activity number 340783463.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luis Quindi — free Get an email when a new federal OSHA severe-injury report for Luis Quindi is published. One employer, no account, unsubscribe in one click.
Establishment
LUIS QUINDI
Site address
4 WEETAMO WAY
City
WESTFORD
State
MA
ZIP
01886
Mailing
748 LAKEVIEW AVE., LOWELL, MA 01850
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

8 citations on file for this inspection.

1903.19 C03

Other-than-serious 1 instance 3 exposed
Issued
Feb 1, 2016
Abate by
Feb 19, 2016
Penalty
Initial $440 · Current $440
29 CFR 1903.19(c)(3): The employer did not submit certification that abatement is complete for each cited violation, in addition to the information required by paragraph (h) of this section, the date and method of abatement and a statement that affected employees and their representatives have been informed of the abatement.  On or about November 19, 2015, the employer failed to submit an abatement certification for the following citation issued on October 30, 2015;  1. Citation 1, Item 1: 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.  Location: 4 Weetamo Way, Westford, MA  This violation was most recently observed on 7/15/2015 at a jobsite located at 4 Weetamo Way, Westford, MA 01886 when installing roofing shingles with pneumatic nail guns, the employees were exposed to eye impalement and laceration hazards where eye protection was not utilized. To abate this violation, the employer must ensure that safety glasses are utilized to protect employees from eye impalement and laceration hazards while utilizing pneumatic nail guns.
Recent events (1)
  • — Z (O) $440

1903.19 D01

Other-than-serious 1 instance 3 exposed
Issued
Feb 1, 2016
Abate by
Feb 19, 2016
Penalty
Initial $440 · Current $440
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.  On or about November 19, 2015, the employer failed to submit abatement documentation for the following citation issued on October 30, 2015;  1. Citation 1, Item 2c: 29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m)  Location: 4 Weetamo Way, Westford, MA  This violation was most recently observed on 7/15/2015 at a jobsite located at 4 Weetamo Way, Westford, MA 01886 where roofing shingles were being installed on an 8-pitch roof, employees were exposed to falls greater than 20-feet, 3-inches while working from a ladder jack scaffold.  To abate this violation, the employer must ensure that ladder jack scaffolds do not exceed the height of 20 feet.
Recent events (1)
  • — Z (O) $440

1926.102 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 30, 2015
Abate by
Nov 19, 2015
Penalty
Initial $2,200 · Current $1,000 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.    Location: 4 Weetamo Way, Westford, MA    This violation was most recently observed on 7/15/2015 at a jobsite located at 4 Weetamo Way, Westford, MA 01886 when installing roofing shingles with pneumatic nail guns, the employees were exposed to eye impalement and laceration hazards where eye protection was not utilized. To abate this violation, the employer must ensure that safety glasses are utilized to protect employees from eye impalement and laceration hazards while utilizing pneumatic nail guns.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2200

1926.502 D15

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 30, 2015
Penalty
Initial $3,080 · Current $1,000 Reduced
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not capable of supporting at least 5,000 pounds per employee attached.    Location: 4 Weetamo Way, Westford, MA     This violation was most recently observed on 7/15/2015 at a jobsite located at 4 Weetamo Way, Westford, MA 01886 where roofing shingles were being installed on an 8-pitch roof, employees were exposed to falls greater than 20-feet, 3-inches while tied off to one anchor point.  To abate this violation, the employer must ensure that an anchor point is provided and utilized for each employee performing work from a roof that requires a fall protection system.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3080

1926.502 D17

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head:  Location: 4 Weetamo Way, Westford, MA   This violation was most recently observed on 7/15/2015 at a jobsite located at 4 Weetamo Way, Westford, MA 01886 where roofing shingles were being installed on an 8-pitch roof, employees were exposed to falls greater than 20-feet, 3-inches while tied off to the front of their safety harnesses opposed to the D-ring located at the center back of their safety harness.  To abate this violation, the employer must ensure that employees tie off to the back D-ring located at the center back of their safety harness.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 K01

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 30, 2015
Abate by
Nov 19, 2015
Penalty
Initial $3,080 · Current $0 Reduced
29 CFR 1926.452(k)(1): Platforms exceeded a height of 20 feet (6.1 m)    Location: 4 Weetamo Way, Westford, MA     This violation was most recently observed on 7/15/2015 at a jobsite located at 4 Weetamo Way, Westford, MA 01886 where roofing shingles were being installed on an 8-pitch roof, employees were exposed to falls greater than 20-feet, 3-inches while working from a ladder jack scaffold.  To abate this violation, the employer must ensure that ladder jack scaffolds do not exceed the height of 20 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3080

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 30, 2015
Penalty
Initial $3,080 · Current $1,000 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    Location: 4 Weetamo Way, Westford, MA    This violation was most recently observed on 7/15/2015 at a jobsite located at 4 Weetamo Way, Westford, MA 01886 where roofing shingles were being installed on an 8-pitch roof, employees were exposed to falls greater than 20-feet, 3-inches while working from a 28-foot Louisville aluminum portable extension ladder that did not extend 3-feet above the upper landing surface.  To abate this violation, the employer must ensure that portable extension ladders extend at least 3-feet above the upper landing surface being accessed.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3080

1926.501 B13

Willful Gravity 10 1 instance 3 exposed
Issued
Oct 30, 2015
Penalty
Initial $15,400 · Current $8,000 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    Location: 4 Weetamo Way, Westford, MA     This violation was most recently observed on 7/15/2015 at a jobsite located at 4 Weetamo Way, Westford, MA 01886 where roofing shingles were being installed on an 8-pitch roof, employees were exposed to falls greater than 20-feet, 3-inches where fall protection was not utilized.  To abate this violation, the employer must ensure that a fall protection system is in place to protect employees working 6 feet of more above a lower level from falling.
Recent events (2)
  • — I (W) $8000
  • — Z (W) $15400

View Luis Quindi's full OSHA safety record →