OSHA Inspection: DUFFIELD ALUMINUM INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DUFFIELD ALUMINUM INC. in 5542 NW 43RD STREET, GAINESVILLE, FL 32653 (NAICS 238160). OSHA activity number 340786052.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Duffield Aluminum INC. — free Get an email when a new federal OSHA severe-injury report for Duffield Aluminum INC. is published. One employer, no account, unsubscribe in one click.
Site address
5542 NW 43RD STREET
City
GAINESVILLE
State
FL
ZIP
32653
Mailing
4566 NW 5TH BLVD. SUITE I, GAINESVILLE, FL 32609
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 17, 2015
Abate by
Aug 25, 2015
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets:  a. On or about July 16, 2015, the employee picking up debris on the ground underneath other employees working on the roof was not wearing a hard hat, being exposed to head injuries.
Recent events (1)
  • — Z (S) $1200

1926.102 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 17, 2015
Abate by
Aug 25, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  a. On or about July 16, 2015, employees using nail guns were not provided safety glasses, being exposed to eye injuries.
Recent events (1)
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 17, 2015
Abate by
Aug 25, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.1053(b)(1): Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access and the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder:  a. On or about July 16, 2015, front of the building, employees were using one side of a Louisville 16-foot ladder that was not able to be extended 3 feet past the landing and was not secured to prevent accidental displacement and a grabrail was not provided.  b. On or about July 16, 2015, left side of the building, employees were using one side of a Louisville 16-foot ladder that was not able to be extended 3 feet past the landing and was not secured to prevent accidental displacement and a grabrail was not provided.  c. On or about July 16, 2015, right side of building, employees were using one side of a Louisville 16-foot ladder that was not able to be extended 3 feet past the landing and was not secured to prevent accidental displacement and a grabrail was not provided.
Recent events (1)
  • — Z (S) $2800

1926.501 B11

Repeat Gravity 10 1 instance 3 exposed
Issued
Aug 17, 2015
Penalty
Initial $9,800 · Current $9,800
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  a. On or about July 16, 2015, roof area, employees installing roofing shingles on a 7:12 pitch roof were not protected from falling up to 12 feet 4 inches by the use of a guardrail system, safety net system, personal fall arrest system or any other type of fall protection method.  Duffield Aluminum Inc. dba Duffield Home Improvements was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 315478008, citation number 01, item number 002 and was affirmed as a final order on August 15, 2011, with respect to a workplace located at 3641 NW 13th Street, Gainesville, Florida 32609.
Recent events (1)
  • — Z (R) $9800

View Duffield Aluminum INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340786052.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.