LAKE CITY, PA —
OSHA Inspection: STERLING TECHNOLOGIES, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of STERLING TECHNOLOGIES, INC. in 10047 KEYSTONE DRIVE, LAKE CITY, PA 16423 (NAICS 326199). OSHA activity number 340792225.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STERLING TECHNOLOGIES, INC.
- Site address
- 10047 KEYSTONE DRIVE
- City
- LAKE CITY
- State
- PA
- ZIP
- 16423
- Mailing
- 10047 KEYSTONE DRIVE, LAKE CITY, PA 16423
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 137
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.1200 H03 III
- Issued
- Sep 22, 2015
- Abate by
- Jan 30, 2016
- Penalty
- Initial $6,300 · Current $3,000 Reduced
8330
General-duty citation text
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used: Employees work with and around sources of heat including, but not limited to, rotational molding machine ovens. Employees have not received training on heat related hazards.
Recent events (3)
- — C (S) $6300
- — F (S) $3000
- — Z (S) $6300
1910.101 B
- Issued
- Sep 22, 2015
- Abate by
- Oct 19, 2015
- Penalty
- Initial $3,600 · Current $2,340 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tank cars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1, which is incorporated by reference as specified in CFR 1910.6, Section 5.8.4, all cylinders were not secured to prevent falling or rolling: a.) Rotational Oven Area - On or about July 27, 2015 a compressed gas cylinder of propane, located on platform 1 for molding machine 280, was free standing and not properly secured to prevent falling; and b.) Rotational Oven Area - On or about September 4, 2015 a compressed gas cylinder of propane, located on the floor next to molding machine 220, was free standing and was not secured by any device to prevent the cylinder from falling, rolling, or getting knocked over.
Recent events (2)
- — I (S) $2340
- — Z (S) $3600
More inspections at Sterling Technologies, INC.
View Sterling Technologies, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340792225.