MAGNOLIA, AR —
OSHA Inspection: ANTHONY OAK FLOORING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ANTHONY OAK FLOORING, INC. in 409 N. VINE ST., MAGNOLIA, AR 71753 (NAICS 321219). OSHA activity number 340807569.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANTHONY OAK FLOORING, INC.
- Site address
- 409 N. VINE ST.
- City
- MAGNOLIA
- State
- AR
- ZIP
- 71753
- Mailing
- 409 N. VINE ST., MAGNOLIA, AR 71753
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321219
- Employees
- 65
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.22 A03
- Issued
- Sep 17, 2015
- Abate by
- Oct 16, 2015
- Penalty
- Initial $3,850 · Current $1,925 Reduced
General-duty citation text
29 CFR 1910.22(a)(3): Every floor, working place, and passageway was not kept free from protruding nails, splinters, holes, or loose boards: The rough know saw walking and working areas were not kept free of loose board and unattached platforms. These conditions exposed employees to trip and fall hazards.
Recent events (3)
- — F (S) $1925
- — C (S) $3850
- — Z (S) $3850
1910.36 G02
- Issued
- Sep 17, 2015
- Abate by
- Oct 16, 2015
- Penalty
- Initial $5,390 · Current $2,695 Reduced
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. Each of the eight rough wood cutting saw station which an employee worked was not at least 28 inches wide at all points for exit access.
Recent events (3)
- — F (S) $2695
- — C (S) $5390
- — Z (S) $5390
1910.37 A02
- Issued
- Sep 17, 2015
- Abate by
- Oct 16, 2015
- Penalty
- Initial $5,390 · Current $2,695 Reduced
General-duty citation text
29 CFR 1910.37(a)(2): Exit routes must be arranged so that employees will not have to travel toward a high hazard area, unless the path of travel is effectively shielded from the high hazard area by suitable partitions or other physical barriers. Employees working in rough knot stations between conveyor systems were required to climb onto and walk over the conveyors to exit the work area, with no other means of egress provided.
Recent events (3)
- — F (S) $2695
- — C (S) $5390
- — Z (S) $5390
1910.303 C03 I
- Issued
- Sep 17, 2015
- Abate by
- Oct 16, 2015
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1910.303(c)(3)(i): Conductors were not spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soledered splices were not spliced or joined mechanically and electrically secured first without solder and then soldered. All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose. The employer had a fan used in the work area with spliced conductors on the flexible cord hard wired into conduit running near the ground level. The splice was not covered with an insulation equivalent to that of the conductors or with an insulating device identified for that purpose, exposing employees to electrical shock and fire hazards.
Recent events (3)
- — F (S) $1540
- — C (S) $3080
- — Z (S) $3080
1910.305 G02 III
- Issued
- Sep 17, 2015
- Abate by
- Oct 16, 2015
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: A flexible cord attached to a foot pedal for conveyor operation in the rough knot saw area had strain relief detached and sheathing pulled back from insulated conductors. This condition exposed employees to electrical and fire hazards.
Recent events (3)
- — F (S) $1540
- — C (S) $3080
- — Z (S) $3080
1910.1030 C01 I
- Issued
- Sep 17, 2015
- Abate by
- Oct 16, 2015
- Penalty
- Initial $3,080 · Current $1,540 Reduced
General-duty citation text
29 CFR 1910.1030(c)(1)(i): The employer having employee(s) with occupational exposure did not establish a written Exposure Control Plan designed to eliminate or minimize employee exposure: The employer did not have written exposure control plan designed to eliminate or minimize employee exposure to bloodborne pathogens when cleaning up blood spills, exposing employees to health hazards.
Recent events (3)
- — F (S) $1540
- — C (S) $3080
- — Z (S) $3080
1910.1030 G02 I
- Issued
- Sep 17, 2015
- Abate by
- Oct 16, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1030(g)(2)(i): The employer did not ensure that each employee with occupational exposure participated in a training program: The employer had not ensured employees cleaning up blood spills in the rough knot saw area had participated in a training program.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Sep 17, 2015
- Abate by
- Oct 16, 2015
- Penalty
- Initial $10,780 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Employees operated eight (8) rough knot saws which were not equipped with guarding to protect the operator and other employees in the area from the hazards created by the point of operation, exposing employees to amputation hazards. Anthony Oak Flooring, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 967110, citation number 1, item number 3 and was affirmed as a final order on May 30, 2014, with respect to a workplace located at 409 N. Vine Street in Magnolia, Arkansas.
Recent events (3)
- — F (S) $3500
- — C (R) $10780
- — Z (R) $10780
More inspections at Anthony OAK Flooring, INC.
View Anthony OAK Flooring, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321219)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340807569.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.