OSHA Inspection: ICS CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ICS CORPORATION in 2225 RICHMOND STREET, PHILADELPHIA, PA 19125 (NAICS 541860). OSHA activity number 340817899.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ICS Corporation — free Get an email when a new federal OSHA severe-injury report for ICS Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
ICS CORPORATION
Site address
2225 RICHMOND STREET
City
PHILADELPHIA
State
PA
ZIP
19125
Mailing
2225 RICHMOND STREET, PHILADELPHIA, PA 19125
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541860
Employees
95
Ownership type
A

5 citations on file for this inspection.

1910.178 M05 II

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 28, 2015
Abate by
Jan 6, 2016
Penalty
Initial $3,500 · Current $2,450 Reduced
29 CFR 1910.178(m)(5)(ii): A powered industrial truck shall not be left unattended when the operator is 25 ft. or more away from the vehicle which remains in view, or whenever the operator leaves the vehicle and it is not in view.    a) Jobsite - The employer did not ensure that the employees operating powered industrial trucks did not leave the trucks unattended while powered.  Observed on or about 27 JULY 2015.
Recent events (2)
  • — I (S) $2450
  • — Z (S) $3500

1910.178 L01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 28, 2015
Abate by
Jan 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a) Jobsite - The employer allowed employees to operate powered industrial trucks without the guidance and preparation provided by proper powered industrial truck training. Noted on or about 27 JULY 2015.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Other-than-serious 4 instances 5 exposed
Issued
Dec 28, 2015
Abate by
Feb 10, 2016
Penalty
Initial $4,200 · Current $2,940 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:      a) Jobsite/Bowe Machines - No guards were provided to protect employees from rotating discs thus exposing employees to caught on hazards. Observed on or about 27 JUL 2015.
Recent events (2)
  • — I (O) $2940
  • — Z (S) $4200

1910.303 B02

Serious Gravity 1 1 instance 5 exposed
Issued
Dec 28, 2015
Abate by
Jan 8, 2016
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Jobsite/Bowe Department - Three (3) wall outlet boxes were not installed in accordance to its listing and labeling exposing employees to electrical hazards.  Observed on or about 27 JUL 2015.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.303 G01

Other-than-serious 1 instance 2 exposed
Issued
Dec 28, 2015
Abate by
Jan 5, 2016
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    a) Jobsite/Printing area - Employees could not readily access the main electrical distribution box due to the storage of fans, carts, and other large objects.  Observed on or about 27 JULY 2015.
Recent events (2)
  • — I (O) $1960
  • — Z (S) $2800

View ICS Corporation's full OSHA safety record →