ERIE, PA —
OSHA Inspection: KOLD-DRAFT INTERNATIONAL, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KOLD-DRAFT INTERNATIONAL, LLC in 1525 EAST LAKE ROAD, ERIE, PA 16511 (NAICS 333999). OSHA activity number 340825785.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KOLD-DRAFT INTERNATIONAL, LLC
- Site address
- 1525 EAST LAKE ROAD
- City
- ERIE
- State
- PA
- ZIP
- 16511
- Mailing
- 1525 EAST LAKE ROAD, ERIE, PA 16511
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333999
- Employees
- 28
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.157 G02
- Issued
- Oct 5, 2015
- Abate by
- Nov 7, 2015
- Penalty
- Initial $2,100 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: A.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, on or about August 4, 2015 and times prior thereto: Employees did not have initial employee fire extinguisher training. Fire extinguishers were deployed in the workplace. The fire extinguishers included but were not limited to multi-purpose dry chemical and water mist extinguishers. A.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, on or about August 4, 2015 and times prior thereto: Employees did not have annual fire extinguisher training. The last fire extinguisher training was held on April 29, 2013. Fire extinguishers were deployed in the workplace. The fire extinguishers included but were not limited to multi-purpose dry chemical and water mist extinguishers.
Recent events (2)
- — I (S) $1500
- — Z (S) $2100
1910.157 E02
- Issued
- Oct 5, 2015
- Abate by
- Oct 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: A.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, on or about August 4, 2015 and times prior thereto: Portable fire extinguishers including, but not limited to, multi-purpose dry chemical extinguishers and water mist extinguishers, that are distributed in the company work areas. The fire extinguishers were not inspected at least monthly.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Oct 5, 2015
- Abate by
- Nov 27, 2015
- Penalty
- Initial $6,000 · Current $5,500 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): A.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, on or about August 4, 2015 and times prior thereto: On or about July 30, 2015, an employee suffered an amputation on the Amada HDS 1303 NT press brake. The press brake was not equipped with protective measures including, but not limited to, guarding devices and/or alternative methods of a safety distance program. B.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, on or about August 4, 2015 and times prior thereto: On or about July 16, 2015, an employee suffered an amputation on the Amada HDS 1303 NT press brake. The press brake was not equipped with protective measures including, but not limited to, guarding devices and/or alternative methods of a safety distance program.
Recent events (2)
- — I (S) $5500
- — Z (S) $6000
1910.212 A03 III
- Issued
- Oct 5, 2015
- Abate by
- Oct 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(iii): Special handtools for placing and removing material(s) was not provided to permit easy handling of material without the operator placing a hand in the danger zone: A.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, on or about August 4, 2015 and times prior thereto: On or about July 30, 2015, an employee suffered an amputation on the Amada HDS 1303 NT press brake. Special handtools were not provide to the employee who was placing parts into the point of operation. B.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, on or about August 4, 2015 and times prior thereto: On or about July 16, 2015, an employee suffered an amputation on the Amada HDS 1303 NT press brake. Special handtools were not provide to the employee who was placing parts into the point of operation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Oct 5, 2015
- Abate by
- Oct 30, 2015
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: A.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, bin area, on or about August 25, 2015 and times prior thereto: Employees were utilizing a cord and plug, four outlet electrical knockout box to power equipment including, but not limited to, a Central Machinery 6-inch bench grinder, and a second cord and plug electrical knockout box. The electrical knockout box was on the table and not mounted to a surface as designed by their listing and labeling. B.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, bin area, on or about August 25, 2015 and times prior thereto: Employees were utilizing a cord and plug, two outlet electrical knockout box to power equipment including, but not limited to, a Samsung cell phone charger. The electrical knockout box was on the table and not mounted to a surface as designed by their listing and labeling.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1910.334 A02 II
- Issued
- Oct 5, 2015
- Abate by
- Oct 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: A.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, bin area, on or about August 25, 2015 and times prior thereto: Employees were utilizing a cord and plug, four outlet electrical knockout box to power equipment including, but not limited to, a Central Machinery 6-inch bench grinder, and a second cord and plug electrical knockout box. The outer jacket of the flexible cord for the four outlet electrical knockout box was frayed within two inches of the box.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV
- Issued
- Oct 5, 2015
- Abate by
- Oct 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): A.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, bin area, on or about August 25, 2015 and times prior thereto: Employees were utilizing a cord and plug, four outlet electrical knockout box to power equipment including, but not limited to, a Central Machinery 6-inch bench grinder, and a second cord and plug electrical knockout box. The use of the flexible cord that was providing power to the electrical box is prohibited as it was being used as a substitute for the fixed wiring of a structure. B.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, bin area, on or about August 25, 2015 and times prior thereto: Employees were utilizing a cord and plug, two outlet electrical knockout box to power equipment including, but not limited to, a Samsung cell phone charger. The use of the flexible cord that was providing power to the electrical box is prohibited as it was being used as a substitute for the fixed wiring of a structure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 I
- Issued
- Oct 5, 2015
- Abate by
- Nov 7, 2015
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: A.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, on or about August 4, 2015 and times prior thereto: The company maintains lockout tagout procedures for equipment including, but not limited to, the Amada press brake, Pines tube bender, and Oak tube cutter. The company last performed periodic inspections of the lockout tagout procedures in 2012.
Recent events (2)
- — I (O) $0
- — Z (S) $2100
1904.29 B01
- Issued
- Oct 5, 2015
- Abate by
- Nov 7, 2015
- Penalty
- Initial $700 · Current $0 Reduced
General-duty citation text
29 CFR 1904.29(b)(1): A Log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent) was not completed in the detail as required by the regulation: A.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, on or about August 4, 2015 and times prior thereto: The company had recorded injuries including, but not limited to, Case# KDI-02-15 and Case# KDI-03-15 on the 2015 OSHA 300 log. Column F did not describe/note the object/agent that directly injured the employee.
Recent events (2)
- — I (O) $0
- — Z (O) $700
1904.39 A02
- Issued
- Oct 5, 2015
- Abate by
- Nov 7, 2015
- Penalty
- Initial $3,500 · Current $3,000 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours: A.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, on or about August 4, 2015 and times prior thereto: The company contacted OSHA on August 3, 2015 to report an amputation injury that occurred on July 30, 2015. The amputation was not reported within 24-hours on the incident. B.) Kold-Draft International, LLC, 1525 East Lake Road, Erie, PA 16511, on or about August 4, 2015 and times prior thereto: The company contacted OSHA on August 3, 2015 to report an amputation injury that occurred on July 16, 2015. The amputation was not reported within 24-hours on the incident.
Recent events (2)
- — I (O) $3000
- — Z (O) $3500
More inspections at Kold-Draft International, LLC
View Kold-Draft International, LLC's full OSHA safety record →
More inspections in this industry (NAICS 333999)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340825785.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.