Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KOLD-DRAFT INTERNATIONAL, LLC

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of KOLD-DRAFT INTERNATIONAL, LLC in 1525 EAST LAKE ROAD, ERIE, PA 16511 (NAICS 333999). OSHA activity number 344427695.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kold-Draft International, LLC — free Get an email when a new federal OSHA severe-injury report for Kold-Draft International, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1525 EAST LAKE ROAD
City
ERIE
State
PA
ZIP
16511
Mailing
1525 EAST LAKE ROAD, ERIE, PA 16511
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333999
Employees
42
Ownership type
A

2 citations on file for this inspection.

1910.133 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 8, 2019
Abate by
Dec 6, 2019
Penalty
Initial $3,720 · Current $2,604 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  A.)  Kold-Draft International, Inc., 1525 East Lake Road Erie PA 16511, on or about November 4, 2019, and times prior thereto:  An employee was wearing prescription eye wear that did not comply with the requirements of ANSI Z87.1. Potential eye hazards were present in the work area.  Eye hazards were created by operations that included, but were not limited to, grinding and the operation of a pop rivet gun.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2604
  • — Z (S) $3720

1910.303 G01 II

Other-than-serious 1 instance 1 exposed
Issued
Nov 8, 2019
Abate by
Dec 6, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  A.)  Kold-Draft International, Inc., 1525 East Lake Road Erie PA 16511, bin area, on or about November 4, 2019, and times prior thereto:  Items including, but not limited to, a plastic tote, a cardboard box, and a pallet with an ice bin on it, were stored within 3-feet of electrical disconnects and an electrical breaker panel box.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Kold-Draft International, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344427695.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.