HOUSTON, TX —
OSHA Inspection: LUIS PEREZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LUIS PEREZ in 423 A W 24TH ST., HOUSTON, TX 77008 (NAICS 238350). OSHA activity number 340827682.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LUIS PEREZ
- Site address
- 423 A W 24TH ST.
- City
- HOUSTON
- State
- TX
- ZIP
- 77008
- Mailing
- 9445 CONCOURCE DR. APT: 275, HOUSTON, TX 77036
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 C02
- Issued
- Aug 13, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: The employer does not ensure that scaffold legs bear on base plates and mud sills. This violation was observed on August 3, 2015, at the job site where an employee was exposed to a 19 foot fall hazard when working on an elevated pump jack scaffold without the scaffold legs bearing on base plates. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all scaffold legs bear on base plates and mud sills.
Recent events (1)
- — Z (S) $2000
1926.451 G01
- Issued
- Aug 13, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: The employer does not protect employees from falling when working on scaffold more than 10 feet above a lower level. This violation was observed on August 3, 2015, at the job site where an employee was exposed to a 19 foot fall hazard when working on an elevated pump jack scaffold without being protected from falling when working more than 10 feet above a lower level. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all employees working from a scaffold 10 feet or more above a lower level are protected from falling.
Recent events (1)
- — Z (S) $2800
1926.452 J01
- Issued
- Aug 13, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.452(j)(1): 29 CFR 1926.452(j)(1): Pump jack brackets, braces, and accessories were not fabricated from metal plates and angles: The employer does not ensure that all brackets and braces are fabricated from metal plates and angles. This violation was observed on August 3, 2015, at the job site where an employee was exposed to a fall hazard when working on an elevated pump jack scaffold without the scaffold braces having been fabricated from metal plates and angles. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure that all brackets and braces are fabricated from metal plates and angles.
Recent events (1)
- — Z (S) $2000
1926.452 J02
- Issued
- Aug 13, 2015
- Abate by
- Aug 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: The employer does not secure the scaffold poles to the structure at the bottom, top, and other points as necessary. This violation was observed on August 3, 2015, at the job site where an employee was exposed to a fall hazard when working on an elevated pump jack scaffold without the scaffold being secured at the bottom and other points as necessary. Pursuant to 29 C.F.R. 1903.19, within ten (10) calendar days of the abatement date, the employer must submit documentation showing that it is in compliance with the standard, including describing the steps that it is taking to ensure scaffold poles are secured to the structure by rigid triangular bracing at the bottom, top, and other points as necessary.
Recent events (1)
- — Z (S) $0
More inspections at Luis Perez
View Luis Perez's full OSHA safety record →
More inspections in this industry (NAICS 238350)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340827682.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.