MADISON, WI —
OSHA Inspection: WISCONSIN EXTERIORS AND DRYWALL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WISCONSIN EXTERIORS AND DRYWALL, INC. in 706 JOHN NOLEN DRIVE, MADISON, WI 53713 (NAICS 238390). OSHA activity number 340845908.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WISCONSIN EXTERIORS AND DRYWALL, INC.
- Site address
- 706 JOHN NOLEN DRIVE
- City
- MADISON
- State
- WI
- ZIP
- 53713
- Mailing
- 3460 MEIER ROAD, MADISON, WI 53718
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238390
- Employees
- 7
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.20 B01
- Issued
- Dec 11, 2015
- Abate by
- Feb 3, 2016
- Penalty
- Initial $2,000 · Current $1,300 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part: The employer had not implemented programs to insure safe working conditions for employees working from scaffolds and engaged in caulking activities.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1926.454 A
- Issued
- Dec 11, 2015
- Abate by
- Feb 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: Employees working from the 2 point suspension scaffold and the fabricated frame scaffold were not trained to recognize scaffold hazards and the procedures to minimize those hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Dec 11, 2015
- Abate by
- Dec 21, 2015
- Penalty
- Initial $2,800 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used: On or about August 13, 2015, the fabricated frame scaffold used at the rear of the building did not have a ladder or other safe access.
Recent events (2)
- — I (S) $2000
- — Z (S) $2800
1926.451 F03
- Issued
- Dec 11, 2015
- Abate by
- Feb 3, 2016
- Penalty
- Initial $2,000 · Current $1,300 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about August 13, 2015, the fabricated frame scaffold used on the rear of the building was not inspected by a competent person.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1926.451 F07
- Issued
- Dec 11, 2015
- Abate by
- Feb 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities were not performed only by experienced and trained employees selected for such work by the competent person: On or about August 13, 2015, the fabricated frame scaffold erected at the rear of the building was not erected under the supervision of a competent person and by trained employees.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 II
- Issued
- Dec 11, 2015
- Penalty
- Initial $2,000 · Current $1,300 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system: On or about August 13, 2015, an employee working from the two-point adjustable suspension scaffold used on the front of the building was not protected from falling by a personal fall arrest system.
Recent events (2)
- — I (S) $1300
- — Z (S) $2000
1926.451 G01 VII
- Issued
- Dec 11, 2015
- Abate by
- Dec 21, 2015
- Penalty
- Initial $2,800 · Current $2,220 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: On or about August 13, 2015, employees working from the fabricated frame scaffold used at the rear of the building were not protected from falls to lower levels.
Recent events (2)
- — I (S) $2220
- — Z (S) $2800
More inspections at Wisconsin Exteriors and Drywall, INC.
View Wisconsin Exteriors and Drywall, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238390)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340845908.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.