GRAND CHUTE, WI —
OSHA Inspection: WISCONSIN EXTERIORS AND DRYWALL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WISCONSIN EXTERIORS AND DRYWALL, INC. in 1565 N. CASALOMA DR., GRAND CHUTE, WI 54915 (NAICS 238310). OSHA activity number 343916664.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WISCONSIN EXTERIORS AND DRYWALL, INC.
- Site address
- 1565 N. CASALOMA DR.
- City
- GRAND CHUTE
- State
- WI
- ZIP
- 54915
- Mailing
- 3460 MEIER RD., MADISON, WI 53718
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 15
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.451 B01 II
- Issued
- Apr 23, 2019
- Penalty
- Initial $5,834 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(ii): Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 1/2 inches (24.1 cm). Exception to paragraph (b)(1): The requirement in paragraph (b)(1) to provide full planking or decking does not apply to platforms used solely as walkways or solely by employees performing scaffold erection or dismantling. In these situations, only the planking that the employer establishes is necessary to provide safe working conditions is required. On and about April, 8, 2019, employees were exposed to falls from scaffolding where working and walking surfaces were not fully decked between the uprights on the access tower when the erection sequence had progressed beyond that point.
Recent events (2)
- — I (S) $3500
- — Z (S) $5834
1926.451 B05 I
- Issued
- Apr 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(5)(i): Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end. On and about April 8, 2019, employees were exposed to falls while erecting a scaffold when the lumber planks used to expand their material landing zone extended approximately 3' beyond the bearing frames.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E04 I
- Issued
- Apr 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(4)(i): A stairrail consisting of a toprail and a midrail shall be provided on each side of each scaffold stairway. On and about April 8, 2019, employees were exposed to falls while climbing a stair tower that had not been equipped with stair rails.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E05 I
- Issued
- Apr 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(5)(i): Ramps and walkways 6 feet (1.8 m) or more above lower levels shall have guardrail systems which comply with subpart M of this part -- Fall Protection; On and about April 8, 2019, employees were exposed to falls while walking and working along walkways on the scaffold that did not have guardrails installed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G02
- Issued
- Apr 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(2): Effective September 2, 1997, the employer shall have a competent person determine the feasibility and safety of providing fall protection for employees erecting or dismantling supported scaffolds. Employers are required to provide fall protection for employees erecting or dismantling supported scaffolds where the installation and use of such protection is feasible and does not create a greater hazard. On and about April 8, 2019, employees were exposed to falls while erecting scaffolding above ten feet. The designated competent person did not evaluate the scaffolding as it was being erected to identify the need to install of fall protection equipment when it became feasible as the scaffold components were installed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 B02
- Issued
- Apr 23, 2019
- Abate by
- May 21, 2019
- Penalty
- Initial $5,834 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.454(b)(2): The correct procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold in question; On and about April 8, 2019, employees were exposed to falls when erecting scaffolding when the employer did not ensure each employee was trained to understand and follow safe work practices specified by the scaffold manufacturer, in that: A) each working level was not completely decked; B) each working level or walkway was not equipped with guardrails; C) access ladders were not used to move between working levels; D) scaffold planks extended more than 12" past the bearing frames; E) personal fall arrest systems were not used when they were feasible.
Recent events (2)
- — I (S) $3500
- — Z (S) $5834
1926.451 E01
- Issued
- Apr 23, 2019
- Penalty
- Initial $11,669 · Current $7,000 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Cross braces shall not be used as a means of access. On and about April 8, 2019, employees were exposed to falls while moving between levels of scaffolding using cross braces and non-climbing frames since no other form of safe access was installed. Wisconsin Exteriors and Drywall, Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1084590, citation number 1, item number 2, and was affirmed as a final order on 1/8/16, with respect to a workplace located at 706 John Nolen Dr. Madison, WI 53713.
Recent events (2)
- — I (R) $7000
- — Z (R) $11669
1926.451 F07
- Issued
- Apr 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person. On and about April 8, 2019, employees were exposed to falls when the employer did not ensure that the scaffolding was being erected under the supervision of a competent person to address fall hazards. The competent person on site did not ensure that scaffold components such as, guardrails, ladder access, planks, and tie in braces to the building structure were installed before erecting the next level above. Wisconsin Exteriors and Drywall, Inc. was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1084590, citation number 1, item number 3b, and was affirmed as a final order on 1/8/16, with respect to a workplace located at 706 John Nolen Dr. Madison, WI 53713.
Recent events (2)
- — I (R) $0
- — Z (R) $0
1904.40 A
- Issued
- Apr 23, 2019
- Abate by
- May 1, 2019
- Penalty
- Initial $834 · Current $0 Reduced
General-duty citation text
29 CFR 1904.40(a): Basic requirement. When an authorized government representative asks for the records you keep under Part 1904, you must provide copies of the records within four (4) business hours. On April 8, 2019, the OSHA 300 logs for the previous three years were requested to be provided within 3 days and had not been provided 10 days after the request.
Recent events (2)
- — I (O) $0
- — Z (O) $834
More inspections at Wisconsin Exteriors and Drywall, INC.
View Wisconsin Exteriors and Drywall, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343916664.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.