SACKETS HARBOR, NY —
OSHA Inspection: LAWMAN HEATING & COOLING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LAWMAN HEATING & COOLING, INC. in 336 BRADY ROAD, SACKETS HARBOR, NY 13685 (NAICS 236220). OSHA activity number 340873991.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LAWMAN HEATING & COOLING, INC.
- Site address
- 336 BRADY ROAD
- City
- SACKETS HARBOR
- State
- NY
- ZIP
- 13685
- Mailing
- 206 AMBROSE STREET, SACKETS HARBOR, NY 13685
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.304 F
- Issued
- Oct 13, 2015
- Abate by
- Oct 21, 2015
- Penalty
- Initial $4,950 · Current $3,465 Reduced
General-duty citation text
29 CFR 1926.304(f) Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: 29 CFR 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 29 CFR 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) Main building, on or about 8-19-15: Two employees were ripping pine boards on a table saw that was not equipped with a spreader. b) Main building, on or about 8-19-15: Two employees were ripping pine boards on a table saw that was not equipped with non kick-back fingers or dogs. c) Main building, on or about 8-19-15: Two employees were operating a table saw that was not equipped a magnetic switch or anti-restart device. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $3465
- — Z (S) $4950
1926.304 I01
- Issued
- Oct 13, 2015
- Abate by
- Oct 21, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) Main building, on or about 8-19-15: Two employees were ripping pine boards on a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 B02
- Issued
- Oct 13, 2015
- Abate by
- Oct 21, 2015
- Penalty
- Initial $2,970 · Current $2,079 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Northeast corner of connector corridor, on or about 8-19-15: Two employees were using a 4"x4" receptacle box that was not being used as designed or as "listed and labeled". ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $2079
- — Z (S) $2970
1926.404 F06
- Issued
- Oct 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Northeast corner of connector corridor, on or about 8-19-15: Employees were operating various portable hand tools through two extension cords that did not have a continuous path to ground due to a missing ground pins.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Lawman Heating & Cooling, INC.
View Lawman Heating & Cooling, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340873991.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.