WATERTOWN, NY —
OSHA Inspection: LAWMAN HEATING & COOLING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LAWMAN HEATING & COOLING, INC. in 600 WILLIAM T. FIELD DRIVE, WATERTOWN, NY 13601 (NAICS 238910). OSHA activity number 340874098.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LAWMAN HEATING & COOLING, INC.
- Site address
- 600 WILLIAM T. FIELD DRIVE
- City
- WATERTOWN
- State
- NY
- ZIP
- 13601
- Mailing
- 206 AMBROSE STREET, SACKETS HARBOR, NY 13685
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 C02
- Issued
- Sep 29, 2015
- Penalty
- Initial $3,960 · Current $2,772 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Southwest corner of building, on or about 8-19-15: One employee was working in an excavation, with the nearest egress ladder located 64 feet away.
Recent events (2)
- — I (S) $2772
- — Z (S) $3960
1926.651 K01
- Issued
- Sep 29, 2015
- Abate by
- Oct 12, 2015
- Penalty
- Initial $4,950 · Current $3,465 Reduced
General-duty citation text
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift: a) Southwest corner of building, on or about 8-19-15: One employee was working in an excavation 5 feet 6 inches to 6 feet 7 inches in depth that was not inspected by a competent person.
Recent events (2)
- — I (S) $3465
- — Z (S) $4950
1926.652 A01
- Issued
- Sep 29, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): a) Southwest corner of building, on or about 8-19-15: One employee was working in an excavation 5 feet 6 inches to 6 feet 7 inches in depth, without an adequate protective system in place.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Lawman Heating & Cooling, INC.
View Lawman Heating & Cooling, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238910)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340874098.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.