CLYDE, OH —
OSHA Inspection: REVERE PLASTICS SYSTEMS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of REVERE PLASTICS SYSTEMS LLC in 401 E ELM ST., CLYDE, OH 43410 (NAICS 326199). OSHA activity number 340918275.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REVERE PLASTICS SYSTEMS LLC
- Site address
- 401 E ELM ST.
- City
- CLYDE
- State
- OH
- ZIP
- 43410
- Mailing
- 401 E ELM ST., CLYDE, OH 43410
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 578
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.137 B02 VIII
- Issued
- Mar 8, 2016
- Penalty
- Initial $4,250 · Current $2,975 Reduced
General-duty citation text
29 CFR 1910.137(b)(2)(viii): Electrical protective equipment was not subjected to periodic tests. Test voltages and the maximum intervals between tests were not in accordance with Table I-5 and Table I-6. (a) Revere Plastics Systems, LLC: On or about September 15, 2015, the employer did not ensure that the electrical protective gloves used by an employee when checking the heater band on the K cell were tested every 6 months. The gloves were most recently tested on October 2013 and had been used by the employee since that date. The employee was at risk of serious injury from electrical shock hazards while working with a 480 volts AC; 3-phase energized circuit. (b) Revere Plastics Systems, LLC: On or about September 15, 2015, the employer did not ensure that the electrical protective gloves used by an employee when changing fuses on press #216 were tested every 6 months. The gloves were most recently tested on July 2011 and had been used by the employee since that date. The employee was at risk of serious injury from electrical shock hazards while working with a 480 volts AC; 3-phase energized circuit.
Recent events (2)
- — I (S) $2975
- — Z (S) $4250
More inspections at Revere Plastics Systems LLC