BLAIRSVILLE, GA —
OSHA Inspection: PANEL BUILT, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of PANEL BUILT, INC. in 303 BEASLEY STREET, BLAIRSVILLE, GA 30512 (NAICS 321992). OSHA activity number 340922525.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PANEL BUILT, INC.
- Site address
- 303 BEASLEY STREET
- City
- BLAIRSVILLE
- State
- GA
- ZIP
- 30512
- Mailing
- P.O BOX 2658, BLAIRSVILLE, GA 30512
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321992
- Employees
- 25
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.22 A01
- Issued
- Dec 23, 2015
- Abate by
- Feb 11, 2016
- Penalty
- Initial $3,500 · Current $2,450 Reduced
E200
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: Panel Built, Inc., Blairsville, GA - Employees were exposed to a possible fire hazard due to an excess and accumulation of combustible dust from the powder coating booth located on elevated surfaces, such as walls, ceiling, piping and other elevated equipment. The employer had not developed a written housekeeping program, on or about 9/10/15. One method to abate this hazard is a periodic cleaning schedule to prevent the accumulation. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1910.107 L04 I
- Issued
- Dec 23, 2015
- Abate by
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
E200
General-duty citation text
29 CFR 1910.107(l)(4)(i): All areas were not kept free of the accumulation of powder coating dust: Panel Built, Inc., Blairsville, GA -Employees were exposed to a possible fire hazard due to an excess and accumulation of combustible dust from the powder coating booth located on elevated surfaces, such as walls, ceiling, piping and other elevated equipment. The employer had not developed a written housekeeping program, on or about 9/10/15. One method to abate this hazard is a periodic cleaning schedule to prevent the accumulation. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 B06
- Issued
- Dec 23, 2015
- Abate by
- Feb 11, 2016
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.106(b)(6): In locations where flammable vapors may be present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition. Sources of ignition may include open flames, lightning, smoking, hot surfaces, frictional heat, sparks (static, electrical, and mechanical), spontaneous ignition, chemical and physical-chemical reactions, and radiant heat: a) Panel Built, Inc., Blairsville, GA - Powder Coating Spraying Area - Employees are exposed to a fire hazard. Employees are required to dispense/pump lacquer thinner and clean beams with rags soaked with lacquer thinner in an aisle area where there is constant employee and forklift traffic, on or about 9/10/5. This Category 2 flammable liquid, with a flashpoint below 100 degrees F, may be used only where there are no open flames or other sources of ignition within the possible path of vapor travel.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.106 E02 II B
- Issued
- Dec 23, 2015
- Abate by
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(2)(ii)(b): The quantity of liquid that may be located outside of an inside storage room or storage cabinet in a building or in any one fire area of a building shall not exceed: (1) 25 gallons of Category 1 flammable liquids in containers (2) 120 gallons of Category 2, 3, or 4 flammable liquids in containers (3) 660 gallons of Category 2, 3, or 4 flammable liquids in a single portable tank. (a) Panel Built, Inc., Blairsville, GA - Spraying Area - Employees are exposed to fire hazard. Employees are required to dispense/pump lacquer thinner and clean beams with rags containing lacquer thinner, a flammable liquid. The quantity of a flammable liquid (WS45 lacquer thinner) located outside of an inside storage room and/or storage cabinet exceed that allowed, on or about 9/10/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 E09 III
- Issued
- Dec 23, 2015
- Abate by
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily: a) Panel Built, Inc., Blairsville, GA - Spraying Area - Employees are exposed to a fire hazard. Employees are required to dispense/pump lacquer thinner and clean beams with rags soaked with lacquer thinner. This combustible waste material (rags) was stored in an open container and not disposed of daily, on or about 9/10/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 C06
- Issued
- Dec 23, 2015
- Abate by
- Mar 25, 2016
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: Panel Built, Inc., Blairsville, GA - In the powder coating area, employees were powder coating beams with powder which is classified as a combustible dust. Electrical equipment such as, but not limited to extension cords, lights (outside of area not separated by a partition and within 5 feet), electrical outlets and fan (outside of booth, but not separated by a partition and within 5 feet), and a radio/speakers (inside of the booth) were subject to combustible residue and not approved for the location, on or about 9/10/15. NOTE: Other equipment outside of but within 20 feet of a spraying area and not separated by partitions shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of Part 1910 for Class I, Division 2 Hazardous Locations.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1910.134 E03 I
- Issued
- Dec 23, 2015
- Abate by
- Feb 11, 2016
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.134(e)(3)(i): The employer did not provide a follow-up medical examination for employees who gave a positive response to any question among questions 1 through 8 in Section 2, Part A of Appendix C, or whose initial medical evaluation demonstrated a need for a follow-up medical examination: Panel Built, Inc., Blairsville, GA - In the powder coating area, employees were required to use half mask and full face, tight fitting respirators for protection against dust and vapors and a follow-up medical examination as recommended by the doctor was not conducted, on or about 09/10/15.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1910.134 E06 I
- Issued
- Dec 23, 2015
- Abate by
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(6)(i): The employer did not obtain from the physician or other licensed health care professional (PLHCP) a written recommendation regarding the employee's ability to use the respirator: Panel Built, Inc., Blairsville, GA - In the powder coating area, employees were required to use half mask and full face, tight fitting respirators for protection against dust and vapors and a the employer did not obtain a physician's written opinon, on or about 09/10/15. Note: The recommendation shall provide only the following information: Any limitations on respirator use related to the medical condition of the employee, or relating to the workplace conditions in which the respirator will be used.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Dec 23, 2015
- Abate by
- Jan 6, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: Panel Built, Inc., Blairsville, GA - In the powder coating area, employees were required to use half mask and full face, tight fitting respirators for protection against dust and vapors. Respirators were observed stored throughout the facility on tables, boxes and nails, on or about 09/10/15
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K01
- Issued
- Dec 23, 2015
- Abate by
- Jan 21, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide respirator training that would ensure each employee could demonstrate knowledge of items in section (i)-(vii): Panel Built, Inc., Blairsville, GA - In the powder coating area, employees were required to use half mask and full face, tight fitting respirators for protection against dust and vapors. Respirators were observed stored in throughout the facility on tables, boxes and nails. Training on respirators was not conducted for new employees and not documented annually for other employees, on or about 09/10/15.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Dec 23, 2015
- Abate by
- Feb 11, 2016
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Panel Built, Inc.- Blairsville, GA - Media Room - Employees are required to use a corrosive chemical, Houghto-Prep ZP (which contains nitric acid and phosphoric acid), to prep and clean exterior beams before powder coating. There was no eyewash system available for immediate use in case of a splash, on or about 09/10/15.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.1200 H03 IV
- Issued
- Dec 23, 2015
- Abate by
- Jan 21, 2016
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): Employees had not been provided with GHS 2012 training including an explanation of the labels received on shipped containers and the workplace labeling system to be used by their employer; the safety data sheet, including the order of information, and how employees can obtain and use the appropriate hazard information: Panel Built, Inc., Blairsvile, GA - In the powder coating area, new employees handle chemicals such as, but are not limited to, WS45 Lacquer thinner(which contains, toluene, acetone, methanol, hexane, and 2 butoxy ethanol), propane, powder coating paints, and Houghto-Prep ZP (contains nitric acid, phosphoric acid). Information and training under the new globally harmonized system (GHS) such as, but not limited to labeling system, and written hazard communication program had not been conducted for new employees, on or about 11/04/15. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.134 F02
- Issued
- Dec 23, 2015
- Abate by
- Feb 11, 2016
- Penalty
- Initial $4,200 · Current $2,938 Reduced
General-duty citation text
Under section 17(c) of the Occupational Safety and Health Act of 1970 and 29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: Panel Built, Inc., Blairsville, GA - In the powder coating area, employees were required to use half mask and full face, tight fitting respirators for protection against dust and vapors and fit testing was not conducted for new employees and not documented annually for other employees, on or about 09/10/15. PANEL BUILT, INC., WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1910.134(F)(2) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1005199 , CITATION NUMBER 01, ITEM NUMBER 1a, ISSUED ON MARCH 5, 2014, AND BECAME A FINAL ORDER ON MARCH 30, 2014.
Recent events (2)
- — I (R) $2938
- — Z (R) $4200
1910.134 E01
- Issued
- Dec 23, 2015
- Abate by
- Feb 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
Under section 17(c) of the Occupational Safety and Health Act of 1970 and 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Panel Built, Inc., Blairsville, GA - In the powder coating area, employees were required to use half mask and full face, tight fitting respirators for protection against dust and vapors and a medical evaluation was not conducted for new employees, on or about 09/10/15. PANEL BUILT, INC., WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 29 CFR 1910.134(E)(1) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1005199 , CITATION NUMBER 01, ITEM NUMBER 1b, ISSUED ON MARCH 5, 2014, AND BECAME A FINAL ORDER ON MARCH 30, 2014. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (R) $0
- — Z (R) $0
More inspections at Panel Built, INC.
View Panel Built, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321992)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340922525.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.