WACO, TX —
OSHA Inspection: TEREX UTILITIES, INC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of TEREX UTILITIES, INC in 7911 PANTHER WAY, WACO, TX 76712 (NAICS 333120). OSHA activity number 340924265.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TEREX UTILITIES, INC
- Site address
- 7911 PANTHER WAY
- City
- WACO
- State
- TX
- ZIP
- 76712
- Mailing
- 7911 PANTHER WAY, WACO, TX 76712
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333120
- Employees
- 117
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 2, 2016
- Abate by
- Feb 19, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: In the hospital area, employees performing the final QA inspection of a Genie S-125 aerial lift were not provided with a written standard operating procedures for using a boom stand to prevent the unintended movement or collapse of the lift's raised boom exposing employees to struck-by, caught in, and crush by hazards.
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
5(a)(1)
- Issued
- Feb 2, 2016
- Abate by
- Feb 19, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: In the hospital area, employees performing the final QA inspection of a Genie S-125 aerial lift were not provided training for using a boom stand to prevent the unintended movement or collapse of the lift's raised boom exposing employees to struck-by, caught in, and crush by hazards.
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
5(a)(1)
- Issued
- Feb 2, 2016
- Abate by
- Feb 19, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: In the hospital area, the employer did not ensure that a boom stand was used while performing QA inspections of a Genie S-125 aerial lift to prevent against unintended movement or collapse of the lift's raised boom exposing employees to struck-by, caught in, and crush by hazards.
Recent events (3)
- — F (S) $7000
- — C (S) $7000
- — Z (S) $7000
1910.147 D04 I
- Issued
- Feb 2, 2016
- Abate by
- Mar 2, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: In the hospital area, the employer did not ensure that an energy isolating device was applied or used prior to servicing a Genie S125 aerial lift exposing employees to struck by, caught in, and crush by hazards.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections at Terex Utilities, INC
View Terex Utilities, INC's full OSHA safety record →
More inspections in this industry (NAICS 333120)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340924265.