OSHA Inspection: ENGINEERED MATERIALS SOLUTIONS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ENGINEERED MATERIALS SOLUTIONS LLC in 39 PERRY AVENUE, ATTLEBORO, MA 02703 (NAICS 331421). OSHA activity number 340962174.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Engineered Materials Solutions LLC — free Get an email when a new federal OSHA severe-injury report for Engineered Materials Solutions LLC is published. One employer, no account, unsubscribe in one click.
Site address
39 PERRY AVENUE
City
ATTLEBORO
State
MA
ZIP
02703
Mailing
39 PERRY AVENUE, ATTLEBORO, MA 02703
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331421
Employees
250
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 29, 2016
Abate by
Jun 14, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Thermostat Metals Cleaning Line:  A pinchpoint created by the takeup reel and hold down device at the end of the Thermostat Metals Cleaning Line was not guarded.
Recent events (1)
  • — Z (S) $7000

1910.333 A

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 29, 2016
Abate by
Mar 21, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:  Thermostat Metals Cleaning Line:  Two workers were installing a horsepower monitor for a pump at the electrical control panel next to the Thermostat Metals Cleaning Line without locking out the power feeding the control panel.