OSHA Inspection: ALLEN ROOFING & SIDING COMPANY

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ALLEN ROOFING & SIDING COMPANY in SCENIC DRIVE & CEDAR MOUNTAIN CT., SAINT PETERS, MO 63376 (NAICS 238160). OSHA activity number 340978824.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Allen Roofing & Siding Company — free Get an email when a new federal OSHA severe-injury report for Allen Roofing & Siding Company is published. One employer, no account, unsubscribe in one click.
Site address
SCENIC DRIVE & CEDAR MOUNTAIN CT.
City
SAINT PETERS
State
MO
ZIP
63376
Mailing
525 OLD STATE ROAD, ELLISVILLE, MO 63021
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
32
Ownership type
A

5 citations on file for this inspection.

1926.451 A06

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Oct 20, 2015
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.451(a)(6):   Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design.  On 10/01/2015, an employee and foreman from Allen Siding and Roofing were installing siding on the side of a residential building located on lot 32 located at the intersection on Scenic Drive and Cedar Mountain Court in St. Peters, MO.  The employee was installing siding from a pump jack scaffolding which was attached to a ladder jack scaffolding.    The plank for the ladder jack scaffolding was supported by a ladder and bracket on one end and the other end of the plank was laying on top of the plank for the pump jack scaffolding.  The scaffolding was not designed or constructed by a qualified person and loaded in accordance with that design.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1926.451 C02 I

Deleted Serious Gravity 10 2 instances 1 exposed
Issued
Oct 20, 2015
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.451(c)(2)(i):   Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.  On 10/01/2015, an employee and foreman from Allen Siding and Roofing were installing siding on the side of a residential building located on lot 32 located at the intersection on Scenic Drive and Cedar Mountain Court in St. Peters, MO.  The employee was working on a pump jack scaffolding that had poles erected on footings which were not level and capable of supporting the loaded scaffold without settling or displacement.  Two out of three poles supporting the pump jack scaffolding were not on level and sound footings to prevent displacement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1926.451 C03

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Oct 20, 2015
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.451(c)(3):   Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement.  On 10/01/2015, an employee and foreman from Allen Siding and Roofing were installing siding on the side of a residential building located on lot 32 located at the intersection on Scenic Drive and Cedar Mountain Court in St. Peters, MO.  The employee was working on a pump jack scaffolding which had poles or legs that were not plumb and braced to prevent swaying or displacement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1926.451 G01

Other-than-serious 1 instance 1 exposed
Issued
Oct 20, 2015
Penalty
Initial $2,975 · Current $2,975
29 CFR 1926.451(g)(1):     Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level.    On 10/01/2015, an employee and foreman from Allen Siding and Roofing were installing siding on the side of a residential building located on lot 32 located at the intersection on Scenic Drive and Cedar Mountain Court in St. Peters, MO. The employee was on pump jack scaffolding approximately 12 foot above the ground. The employee was wearing a body harness, but was not tied off.  The employee was not protected from falling to the lower level.
Recent events (2)
  • — I (O) $2975
  • — Z (S) $2975

1926.452 J02

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Oct 20, 2015
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1926.452(j)(2):   Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.   On 10/01/2015, an employee and foreman from Allen Siding and Roofing were installing siding on the side of a residential building located on lot 32 located at the intersection on Scenic Drive and Cedar Mountain Court in St. Peters, MO.  The employee was working on a pump jack scaffolding, which had a leg that was not secured to the structure by rigid triangular bracing or equivalent at the bottom.  The pole or leg in the rear of the residence was not secured by triangular bracing or equivalent at the bottom.