Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VPI CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VPI CORPORATION in 3123 S. 9TH STREET, SHEBOYGAN, WI 53081 (NAICS 326192). OSHA activity number 340996362.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch VPI Corporation — free Get an email when a new federal OSHA severe-injury report for VPI Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
VPI CORPORATION
Site address
3123 S. 9TH STREET
City
SHEBOYGAN
State
WI
ZIP
53081
Mailing
P.O. BOX 451, SHEBOYGAN, WI 53082
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326192
Employees
34
Ownership type
A

5 citations on file for this inspection.

1910.22 A01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Dec 24, 2015
Abate by
Jan 11, 2016
Penalty
Initial $2,380 · Current $0 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.  a)    On or about 10/19/2015, The room with the Cumberland Granulator in it had PVC resin on top of the electrical cabinet that was approximately 5" deep.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2380

1910.147 C06 I

Serious Gravity 1 1 instance 27 exposed
Issued
Dec 24, 2015
Abate by
Feb 2, 2016
Penalty
Initial $1,785 · Current $1,785
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a)    On or about 10/19/2015, The company had not completed annual audits of their energy control procedures with each authorized employee and certifying the inspections during 2014 or 2015.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $1785

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 24, 2015
Abate by
Feb 2, 2016
Penalty
Initial $3,570 · Current $3,570
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a)    On or about 10/08/2015, employee was injured while cleaning the Cumberland Granulator when the slide gate nip caught his thumb.
Recent events (2)
  • — I (S) $3570
  • — Z (S) $3570

1910.219 D01

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Dec 24, 2015
Abate by
Feb 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a)    On or about 10/19/2015, there was an unguarded opening on the Cumberland Granulator approximately 15" x 20" where a lexan guard was missing exposing ingoing nip points for the belt and pulley.  b)    On or about 10/19/2015, there was an unguarded opening on the Cumberland Granulator approximately 31" w by 9" high above the welded plate exposing ingoing nip points for the belt and pulley.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E03 I

Deleted Serious Gravity 5 2 instances 2 exposed
Issued
Dec 24, 2015
Abate by
Feb 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):  a)    On or about 10/19/2015, there was an unguarded opening on the Cumberland Granulator approximately 15" x 20" where a lexan guard was missing exposing ingoing nip points for the belt and pulley.  b)    On or about 10/19/2015, there was an unguarded opening on the Cumberland Granulator approximately 31" w by 9" high above the welded plate exposing ingoing nip points for the belt and pulley.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View VPI Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340996362.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.