Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DIVERSITECH CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DIVERSITECH CORPORATION in 1512 OLD COVINGTON HWY, CONYERS, GA 30012 (NAICS 327390). OSHA activity number 341027969.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Diversitech Corporation — free Get an email when a new federal OSHA severe-injury report for Diversitech Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1512 OLD COVINGTON HWY
City
CONYERS
State
GA
ZIP
30012
Mailing
1512 OLD COVINGTON HWY, CONYERS, GA 30012
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
99
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 2 exposed
Issued
Feb 12, 2016
Abate by
Mar 10, 2016
Penalty
Initial $3,400 · Current $2,250 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to strike-by hazards:  a) Plant - On or about 10/29/15 and at times prior thereto employees loosened and displaced the raw material hoppers of injection molding machines #1 to #8 during maintenance, service and clean-up. The loose hoppers were not secured to prevent accidental  tilting on the workers.   b) Plant - On or about 10/29/15 and at times prior thereto employees conducted maintenance, servicing, and clean-up of injection molding machines.  The row material hoppers of machines #5, #6, #7 were installed unsafely with only two bolts instead of four, as required by the design of the equipment.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3400

1910.23 C03

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 12, 2016
Abate by
Mar 10, 2016
Penalty
Initial $3,400 · Current $2,250 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards : Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard:  a) Plant - On or about 10/29/15 and at times prior thereto employees climbed on top of the injection molding machines including (but not limited to) machines #5, #6, #7 and #8 to change molds and conduct maintenance/repairs. No fall protection was in use to prevent falls from a maximum elevation of 12 ft. onto the concrete floor.  Or in the alternative:  29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board.  a) Plant - On or about 10/29/15 and at times prior thereto employees climbed on top of the injection molding machines including (but not limited to) machines #5, #6, #7 and #8 to change molds and conduct maintenance/repairs. No fall protection was in use to prevent falls from a maximum elevation of 12 ft. onto the concrete floor.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3400

View Diversitech Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341027969.